1.  Introduction

Thank you for choosing to buy our Oceanic steam generator, please take the time to read these 

instructions before you begin as they contain important information about the installation and 

maintenance requirements.

“Oceanic” heavy duty steam generators are available in specifications from 6kw to 12kw and are 

equipped with a programmable thermostatic controller. The controller is set with the time and 

day and allows you to program the generator to turn on and off automatically when you require, 

the generator can also bet set to clean itself automatically. Once these settings have been saved 

the machine can be left to work on it’s own. The machine still must be checked on a regular basis 

for safety.  

It is also possible to have the generator working off a push button which you place outside of the 

steam room, when customers push the button it illuminates and they get 30 minutes of steam.  

The machine can also just work on a count down timer for say the next 90 minutes. 

Our display tells you everything that the generator is doing, if it takes in water, heats, reached 

temperature, draining, descaling, light on, fan on, timer set.  

You can also Lock the keys so other users can’t play with the settings.  light of the steam room, the 

automatic drain valve, key-lock, alter the temperature display between Centigrade and Fahrenheit; 

as well as displaying the steam generator‘s status by the 8 LED’s on the panel, heating, water inlet, 

temperature, drain status etc. note also that one “OC-D” controller can control multiple “Oceanic” 

steam generators.

Every “Oceanic” steam generator is thoroughly tested before leaving the factory so there may be 

the remains of water inside the boiler.

2.  Important Notes

•  Read the manual before installation and operation.

•  This Equipment must be installed by competent person. 

•  This equipment must be connected to an all pole isolator

•  Disconnect the power supply before exposing electrical connections.

•  Confirm the correct voltage to your steam generator 1 or 3 phase.

•  For hard water areas please use a water softener. 

•  Water supply must have maximum of 1 bar pressure, we recommend the use of a pressure 

reducing valve if necessary

3.  Safety Precautions 

•  Elderly persons, pregnant women, or these suffering heart disease, high blood pressure, 

diabetes or not in good health are advised to seek medical opinion before using a steam room.

•  Do not smoke in the steam room.

•  Avoid using the steam room immediately after strenuous exercise. 

•  Do not use the steam room when under the influence of alcohol.

•  Leave the steam room at once if you feel sleepy, sick or uncomfortable.

•  Ensure there is good ventilation for the steam room.

•  We do not recommend that children under 16 use this product.

•  Commercial operators should post a notice of these precautions in a prominent position.

Steam entering the steam room will be scalding hot; take care to position the inlet nozzle 

away from where users will sit and/or provide adequate guarding, post a notice to caution 

users.

Содержание OCD-60

Страница 1: ...PRODUCT IMAGE Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam Heavy Duty Commercial STEAM GENERATOR 15 06 17...

Страница 2: ...e 2 OC D Controller Parameters 8 5 7 Temperature Sensor Parameters 8 6 OC A Controller Description 9 7 Installation 10 7 1 Generator Size 10 7 2 Steam Generator Location 11 7 3 Water and Steam Connect...

Страница 3: ...as well as displaying the steam generator s status by the 8 LED s on the panel heating water inlet temperature drain status etc note also that one OC D controller can control multiple Oceanic steam g...

Страница 4: ...Sauna Steam Oceanic Saunas 01902 450 550 sales oceanic saunas co uk 4 Steam Generator Manual 4 Steam Generator Parts 4 3 2 1 9 8 7 6 5 10 15 11 11 12 13 14 17 18 19 20 16...

Страница 5: ...ction 9 Relay Circuit Board Electrically operated switches for elements 10 Overheat switch Boil dry protector operates at 105oC Use Pin to reset 11 Louvers Ventilation 12 Main Power Cable Entry Cable...

Страница 6: ...box has to be carried out by an authorised electrician In case of a warranty claim you are kindly requested to present a copy of the invoice from the electrician Model Power Current amps Size mm Stea...

Страница 7: ...e relief valve Operates if the pressure in the boiler exceeds 1 2kg c m2 Supplied 10 Brass T junction 3 4 to 3 4 and 1 2 brass fitting to fit steam pipe and pressure relief valve Supplied 11 Brass T 3...

Страница 8: ...Sauna Steam Oceanic Saunas 01902 450 550 sales oceanic saunas co uk 8 Steam Generator Manual 1 1 2 2 5 5 6 6 7 8 13 14 16 15 17 18 19 20 20 3 3 4 Jubilee clip cable tie Jubilee clip cable tie...

Страница 9: ...pipe Use a 3 4 female cap to block off the secondary outlet 9 9 10 13 13 13 10 12 11 5 2 Steam Pipe Connection Options Important note Steam outlet must not be reduced Mains in 230V 1N 400V 3N 230V li...

Страница 10: ...AVE J7 R CONTROL D9 J6 TEMP2 D8 D7 D6 D5 D4 D3 D2 D1 J4 NO NC Water Inlet AC power adapter AC230V DC24V Water Inlet Valve Drain Valve Descale Liquid Inlet Pump OC S Controller 2 r Circuit Diagram 2 4...

Страница 11: ...OCD 90 535 260 380 25 135 45 OCD 120 535 260 380 25 135 45 6 Parameters 6 2 Clearance distances 200mm 300mm 400mm 500mm A B C E D F 6 1 Steam Generator Frame Sizes 6 3 Ventilation Ensure air flow into...

Страница 12: ...D 30 60 o C 155 x 115 x 20 MODEL Detected Scope Max Cut out Temperature Size mm o C o F o C o F L W H OC S 0 110 32 230 60 248 76 42 27 6 4 Table 2 OC D Controller Parameters 6 5 Temperature Sensor P...

Страница 13: ...adequate guarding post a notice to caution users Keep the number of right angle bends to a minimum and ensure that the run does not create a trap into which condensate would gather and cause a blocka...

Страница 14: ...ace first then hang the generator by the 2 keyhole shaped holes in the back plate Then with the front cover removed fix the 3rd screw to secure the unit in place 10m The steam generator can be install...

Страница 15: ...ler and temperature probe OC D controller is waterproof and can be installed inside or outside the steam room according to customer preference i For a better connection and to eliminate any future con...

Страница 16: ...e main circuit board but you can add your own fused spur for extra protection if you prefer 7 7 Installing a Fan Same as above for a light 7 8 Connecting to descaler i OCD Generator is able to run aut...

Страница 17: ...o Water Supply 10 Generator Has Overheated 11 Fan On 12 Light On 13 Keypad Locked 14 Auto Timer Set 15 Fan On Decrease 16 Setting 17 Drain Must Be Off Increase 18 Light On Left Scroll 19 Machine On Of...

Страница 18: ...uttons to set the hours minutes and day 9 4 Setting Temperature i You can set the temperature between 35 and 600 C and between 95 and 1400 F ii If you are a novice user we advise to start at around 38...

Страница 19: ...am specfiic times for the generator to turn on and off throughout the day Once setup machine will remember to turn on or off at these same times everyday vi You can choose in the morning from between...

Страница 20: ...d it You must remember though that once the cycle has been completed you must turn the Tick to a X to turn the weekly descale off To setup descaling push Push to enter iv The default is Sunday between...

Страница 21: ...ng out of steam nozzle Water Level Probe Remove and clean water level probe Check connections to and from water level probe Check water pressure is 1bar Circuit breaker tripping out Element failure Lo...

Страница 22: ...the water for hardness and arrange the descaling routine accordingly High levels of hardness descale once every 50 to 100 hours of operation Medium levels of hardness descale once every 100 to 250 hou...

Отзывы: