background image

14/11/2022 

912S-03718 v01.00 

15

PLB3 USER MANUAL

4. 

BEACON REGISTRATION

!

 

It is the owner’s responsibility to register this beacon with the appropriate National 

Authority before operation.

The preferred method of registration is online. Documentation is provided within the packaging with 

information regarding registration with the relevant body to comply with the configuration of the 

beacon.

4.1 

Advice to owners of Personal Locator Beacons (PLBs).

Registration of 406 MHz satellite PLBs:

• 

Registration with the National Authority is 

mandatory

 due to the global alerting system.

• 

The information provided in the registration card is used for rescue purposes only.

• 

See below for details on how to register your beacon upon completion of the sales transac-

tion. Before a beacon enters service, it 

must

 be registered with the National Authority. 

• 

If the beacon is being transferred to a new owner, the current owner needs to inform the 

National Authority of the name and address of the new owner.

• 

The subsequent owner of the beacon is required to provide the National Authority with the 

information as shown in the owner registration card.

• 

This obligation transfers to all subsequent owners.

• 

Some National Authorities require periodic renewal. It is the owner’s responsibility to 

ensure registration details are current and valid.

4.2 

Country Specific Registration information

USA 

 

NOAA-Sarsat, USMCC, NSOF, E/SPO53, 1315 East West Hwy, Silver Spring, MD, 20910 

 

Fax: (1.301) 8174565, Tel: (1.301) 8174515 (1.888) 2127283 

 Email: 

[email protected]

, Web: 

www.beaconregistration.noaa.gov/

CANADA 

 

Beacon Registry, CMCC Trenton, 8 Wing Trenton, Box 1000 Stn Forces, Astra, Ontario, K0K 3W0 

 

Fax: +1 877 406 3298, Tel: +1 800 211 8107 / +1 613 965 7265 

 Email: 

[email protected]

, Web: 

www.cbr-rcb.ca

UK 

 

Distress & Security Beacon Registry, Pendennis Point, Castle Drive, Falmouth, TR11 4WZ 

 

Fax: +44 (0) 13 2631 9264, Tel: +44 (0) 20 3817 2006 

 Email: 

[email protected]

, Web: 

www.gov.uk/406beacon

AUSTRALIA 

 

Australian Maritime Safety Authority, GPO Box 2181, Canberra, Australia, ACT 2601 

 

Fax: 1800 406 329 (+61 2 9332 6323 (Int.)), Tel: 1800 406 406 (+61 2 6279 5766 (Int.) 

 Email: 

[email protected]

, Web: 

www.amsa.gov.au/beacons

NEW ZEALAND 

 

JRCC NZ, Avalon Studios, Percy Cameron Street, P.O. Box 30050, Lower Hutt, 5040 

 

Fax: +64 4 577 8041, Tel: +64 4 577 8030  +64 4 577 8034 

 Email: 

[email protected]

, Web: 

www.beacons.org.nz

For other countries visit: 

www.406registration.com/countriessupported.aspx

Содержание rescueME PLB3

Страница 1: ...User Manual www oceansignal com English Personal Locator Beacon with AIS and RLS PLB3 OWNER DETAILS Name Organisation CONTACT Tel Email ...

Страница 2: ...change specifications and other information contained in this manual as part of our continual improvement process No part of this manual may be reproduced stored in a retrieval system or transmitted in any form electronic or otherwise without the prior permission of Ocean Signal Ltd No liability can be accepted for any inaccuracies or omissions in this manual Ocean Signal and rescueME are register...

Страница 3: ... 12 clear to avoid possible injury Following activation ensure the antenna is fully released and the unit has the best possible view of the sky for optimal performance If the strobe light does not start flashing manually switch the PLB3 on by pressing the ON Key Always turn off the PLB3 immediately after you have been rescued to avoid interference with other users To turn off the beacon press and ...

Страница 4: ... False Alerts 12 3 TESTING 12 3 1 Functional test 13 3 2 GNSS Test 14 4 BEACON REGISTRATION 15 4 1 Advice to owners of Personal Locator Beacons PLBs 15 4 2 Country Specific Registration information 15 5 LIFE JACKET INSTALLATION 16 5 1 Remove the Activation Slider 17 5 2 Securing the Activation System 17 5 3 Attach the tape to the Activation Slider 18 5 4 Insert the Activation Slider 19 5 5 Attach ...

Страница 5: ... Return Link Service RLS is a free of charge global service available to Cospas Sarsat RLS compatible beacons The RLS feature is an indication on the PLB3 that confirms to the User that the distress signal from the PLB3 has been localised by the Cospas Sarsat system and is being sent to the SAR authorities It does NOT mean that a search and rescue mission has been launched but only confirms that t...

Страница 6: ...omplies with EN62479 EU and RSS 102 Canada 1 6 Warnings Take great care to keep well clear of eyes and face as the antenna will be released very quickly Keep at least 30cm 12 clear to avoid possible injury Contains Lithium batteries store between 30 C 22ºF to 70 C 158ºF DO NOT ATTEMPT TO REPLACE THE BATTERIES YOURSELF unauthorised opening and battery replacement may put your life at risk do not sh...

Страница 7: ... s in the box 1 PLB3 2 Belt Webbing attachment bracket 3 Oral Tube attachment bracket 4 Activation Tape 5 Antenna Rewind Tool 6 Attachment Lanyard 7 Activation Slider Armed Cover 8 Product Documentation and Quick Start Guide PLB3 USER MANUAL 1 2 3 4 5 6 7 8 ...

Страница 8: ...devices using Near Field Communication NFC NFC technology allows communication between two electronic devices over a distance of 4cm 1 5 or less The benefit of using NFC in the PLB3 is that the power used for communication comes from the mobile device and not the beacon The Ocean Signal mobile App allows a user to access the PLB3 and see the programmed details and the latest test results giving a ...

Страница 9: ...verview 1 Antenna behind activation slide 2 Activation Slide 3 Arming Slide shown in safe position 4 ON Key for manual activation 5 Strobe and Indicator LED 6 TEST OFF Key 7 Arming Slide in armed position PLB3 Controls shown in activated condition 1 2 3 4 5 6 7 ...

Страница 10: ...ecome dislodged from the jacket s oral tube it should be repositioned 2 1 Activation when installed in a life jacket When correctly packed in a life jacket the PLB3 will activate when the life jacket inflates Should the life jacket fail to fully inflate it may be necessary to assist the Activation Slide by pulling on the Activation Tape to fully release the Activation Slide 2 2 Manual activation O...

Страница 11: ... 2 5 s 121MHz Reply received x1 Every 2 5 s 2 3 2 LED Indications for units configured with non RLS Protocol LED When Transmit GNSS x1 Every 5 s Searching x3 Once Fix acquired x5 At transmit 406MHz No Fix x5 At transmit 406MHz Fix acquired x8 At transmit AIS No Fix x8 At transmit AIS Fix acquired x1 Every 2 5 s 121MHz x1 Every 2 5 s The AIS transmissions will show as 8 flashes 1 every 2 seconds as...

Страница 12: ...the PLB3 is accidentally activated it should be immediately turned off If the unit was active for more than 30 seconds the nearest Coast Guard Centre or Rescue Coordination Centre should be contacted to explain that the PLB3 has been activated in error and there are no follow up rescue actions required See inside the back cover for information required in the event of a false activation If appropr...

Страница 13: ...ED Indications for units configured with non RLS Protocol No of Flashes Functional Test Pass Fail 1 0 to 59min 1hr to 1hr 59min 121 5MHz homer 2 2hrs to 3hrs 59min 406MHz power 3 4hrs to 5hrs 59min AIS signal 4 6hrs to 7hrs 59min AIS Power 5 8hrs to 9hrs 59min Battery failure 6 10hrs No GNSS Because this test transmits a short burst on the aircraft distress frequency of 121 5MHz please only carry ...

Страница 14: ...cated by long red followed by a number of green LED flashes and an unsuccessful test will be indicated by a number of red LED flashes The number of flashes indicates the number of GNSS tests remaining e g 7 flashes 7 tests remaining The test result flashes will be repeated after 2 seconds If there are 10 or more tests remaining then the LED will flash 10 times only repeated The PLB3 has the capaci...

Страница 15: ...egistration card This obligation transfers to all subsequent owners Some National Authorities require periodic renewal It is the owner s responsibility to ensure registration details are current and valid 4 2 Country Specific Registration information USA NOAA Sarsat USMCC NSOF E SPO53 1315 East West Hwy Silver Spring MD 20910 Fax 1 301 8174565 Tel 1 301 8174515 1 888 2127283 Email beacon registrat...

Страница 16: ...er is permanently attached to the cover please see the separate instruction sheet available from the Ocean Signal website Once completed the installation should be tested to ensure correct activation takes place Refer to the life jacket manufacturer for the manual inflation process The PLB3 is activated when the activation slider is pulled from the front of the device by the tension in the tape cr...

Страница 17: ...d face as the antenna will be released very quickly Keep at least 30cm 12 clear to avoid possible injury Slide the red arming tab down Slide the grey slide sideways off the unit Turn off the PLB3 by pressing the TEST OFF Key until the LED flashes red twice and release 5 2 Securing the Activation System 1 To prevent accidental loss use the provided length of cord to tether the Antenna Rewind tool A...

Страница 18: ...to the Activation Slider 1 Pass the Activation Tape down through the inner slot in the Activation Slider 2 Pass the Activation Tape up through the outer slot in the Activation Slider 3 Pull the tape through the slider to leave approximately 5cm 2 free at the end 4 Pass the other end of the Activation Tape across the underside of the Activation Slider and pull tight to trap the tape to the slider ...

Страница 19: ... the tool through the hole in the top of the PLB3 and place over the antenna just behind the end cap 3 Rotate the tool anticlockwise until fully wound Hold the tool keeping the antenna coiled Do not remove the tool until the slider is in place 4 Push the Activation Slider into place ensuring the tape lies flat between the slider and the PLB3 5 Release and remove the rewind tool to allow the antenn...

Страница 20: ...ral tube 5 Feed the tape into the rearmost slot in the side of the PLB3 so that it emerges from the front slot 6 Loop the tape around and into the foremost slot on the side of the PLB3 so that it emerges alongside the inserted tape 7 Pull approximately 25mm 1 of tape through the slots in the PLB3 8 Clip the PLB3 into the Oral Tube bracket taking care not to trap any loose tape 9 Pull the tape tigh...

Страница 21: ...ided to protect the PLB3 from accidental activation if the grey slide is knocked or otherwise moved under the life jacket cover After arming the PLB3 fit the protective cover then clip the protective cover into the slots immediately adjacent to the arming slider Make sure that both sides of the cover are clipped in place Ensure the PLB3 is securely tied to a fixed point on the life jacket that wil...

Страница 22: ...ay cause the plastics to deteriorate Ensure the antenna is free to unwind Should the PLB3 turn on during cleaning make sure it is turned off as quickly as possible by pressing and holding the TEST OFF Key until the LED flashes red twice and release 7 2 Batteries The PLB3 contains Lithium iron batteries for long operating life The battery must be replaced either prior to the expiry date shown on th...

Страница 23: ...the beacon has been decommissioned 7 4 Transport When shipping your PLB3 the following guidance and regulations should be followed but you are advised to contact your nearest battery replacement centre or Ocean Signal prior to shipping as regulations may have changed Always pack your PLB3 securely in a stout cardboard carton Ocean Signal advises that you keep the original packaging in case of retu...

Страница 24: ...nsity 1 candela Flash Rate 20 30 per minute Infra Red Strobe Light Type IR LED Light Colour 850nm Intensity 7 5mW sr Flash Rate 20 30 per minute Battery Type Lithium Iron Disulfide Li FeS2 Operating lifetime 24hours 20ºC 4ºF Lithium Metal Weight for air transport 2g per battery Replacement Interval 6 years from date of manufacture or 5 years from being placed into service GNSS Receiver Satellite C...

Страница 25: ...is approved for use in Canada with AIS only under RSS287 7 6 3 European Declaration of Conformity Hereby Ocean Signal Ltd declares that the radio equipment type PLB3 is in compliance with Directive 2014 53 EU Country of Intended Use The Country of Intended Use table is an EU requirement only Austria P Finland P Latvia P Romania P Belgium P France P Lithuania P Slovakia P Bulgaria P Germany P Luxem...

Страница 26: ...aterial or accessory that is not manufactured by Ocean Signal the consumer will be covered by the guarantee warranty offered to Ocean Signal by the manufacturer or supplier of such a component for product which has not been fully paid for for any product supplied by Ocean Signal to a customer under an alternative warranty or commercial agreement for the cost of shipping product to and from the cus...

Страница 27: ...Centre or Rescue Coordi nation Centre to explain that the PLB3 has been activated in error and there are no follow up rescue actions required Information required is the 15 digit HEX ID UIN shown above the date time duration and cause of activation the location at the time of de activation ATTACH YOUR REGISTRATION DOCUMENTS HERE FOR SAFE KEEPING ...

Страница 28: ...Ocean Signal Ltd Unit 4 Ocivan Way Margate CT9 4NN United Kingdom info oceansignal com www oceansignal com ...

Отзывы: