OBID i-scan
®
Installation
ID ISC.LRU2000
FEIG ELECTRONIC GmbH
Page 56 of 56
M60801-0de-ID-B.doc
E N G L I S H
•
Interfaces
- RS232
- RS485 / RS422 (selectable)
- Ethernet (TCP/IP) (only device version with
ACC)
•
Protocol modes
- FEIG ISO Host
- Buffer Reader Mode (Data Filtering and
buffering)
•
Supported transponders
- 18000-6-B
- EPC class 1 gen
- EPC class 1 gen 2
•
Optical indicators
6 LEDs for operating status diagnostics
Ambient
•
Temperature range
- Operating
- Storage
-25°C to +55°C (-25°C to +70°C)
-25°C to +85°C
•
Vibration
EN60068-2-6
10 Hz to 150 Hz : 0.075 mm / 1 g
•
Shock
EN60068-2-27
Acceleration
: 30 g
Applicable standards
•
RF approval
- Europe
- USA
EN 302 208
EN 300 220
FCC 47 CFR Part 15
•
EMC
EN 301 489
•
Safety
- Low-Voltage
- Human Exposure
EN 60950
EN 50364
Содержание i-scan ID ISC.LRU2000-A-EU
Страница 29: ......