OBID i-scan
®
Installation
ID ISC.LRU2000
FEIG ELECTRONIC GmbH
Page 49 of 56
M60801-0de-ID-B.doc
E N G L I S H
3
Operating and Display Elements
3.1 LEDs
Table 3-1 shows the LED configuration.
Abbreviation
Description
LED V1 (green)
"RUN-LED 1"
-
Indicates proper running of the internal Reader software (DSP)
LED V2 (blue)
Diagnostic 1: RF communication / EEPROM status
-
Short flashing indicates errorless communication with a
transponder on the RF interface
-
Flashes alternately with V1 after a reset following a software
update
-
Flashes alternately with V1 in case of a data error when
reading the parameters after a reset
LED V3 (yellow)
Diagnostic 2: Host communication
-
Short flashing indicates sending of a protocol to the host on the
RS232/RS485 interface
LED V4 (yellow)
Reserved
LED V5 (red)
Diagnostic 4: RF warning
-
Comes on during Reader initialization after power-on or after a
reset.
-
Comes on when there is an error in the RF section of the
Reader. The error type can be read out via software over the
RS232/RS485 interface
LED V6 (green)
(only device
version with ACC)
"RUN-LED 2"
-
Indicates proper running of the AC Controller
Table 3-1: LED configuration
Содержание i-scan ID ISC.LRU2000-A-EU