Tion 

of Componen

Ts

0552-06   8” x 16” rectangular adjuster pad

The wider 8” x 16” Rectangular Adjuster pad can be used either individually or 

combined to allow those with a shorter humerus to allow the forearm and elbow 

to rest and stabilize on a flat surface. Additionally, these can be used as the 7” x 

12 adjuster pads are utilized, with a wider support.  

4402-06   7” x 12” rectangular adjuster pad

The 7” x 12” Rectangular Adjuster pads are used either individually or combined to 

reduce lumbar lordosis and/or increase chest height to allow for shoulders to natural-

ly decend out of the plane of the cervical and thoracic spine. These pads offer a wide 

range of flexibility for general patient positioning and stabilization.

8” halF 

round 

bolster

 8” semi 

round 

bolster

1581-06   8” x 26” half round bolster
5932-06   8” x 26” semi-round bolster

These bolsters may be placed under the patient’s ankles to enhance positioning stabil-

ity. Two different bolster sizes are provided to allow for patient comfort.  

description of components - continued

Содержание Spine Positioning System

Страница 1: ...so Support Pad 2 7 x 12 rectangular adjuster pads 2 8 x 16 rectangular adjuster pads 2 Contoured Torso Wedges pictured here with small wedge 1 Radiolucent frame with adjustable face rest 1 carry case...

Страница 2: ...t to change without notice and should not be construed as a commitment by Oakworks Inc Oakworks Inc assumes no responsibility for any errors that may appear in this document nor does it make expressed...

Страница 3: ...ns 2 3 Symbol Identification 4 Description of Components 5 7 Directions for Use 8 15 Maintenance Service 17 21 cleaning disinfecting 17 maintenance 18 19 list of parts 20 specifications 21 warranty 21...

Страница 4: ...omfort and imaging needs for all spinal column procedures WARNING warnings A patient safety strap is required during all procedures Follow normal and required safety protocol for all procedures where...

Страница 5: ...l cam locks are secure before relinquishing support of the positioning assembly The Cervical Support System see page 5 has metal parts that can cause back scatter of x rays When x rays are present wea...

Страница 6: ...mbol when used in this manual or on product labels indicates that the product should be protected from moisture The humidity specifications for Transport Storage are listed on page 23 This symbol when...

Страница 7: ...Crescent face rest pad One cam lock facilitates cervical flexion and extension 1 Crescent Face Rest Pad PN EM2410 SP 1 Contoured Torso Support Pad pn 0546 06 2 7 x 12 rectangular adjuster pads pn 4402...

Страница 8: ...enhance patient stability by reducing sway while in the device 0550 06 small CONTOURED Torso WEDGE 0554 06 large CONTOURED Torso WEDGE The Contoured Torso Wedge is constructed of dense foam and cover...

Страница 9: ...gular Adjuster pads are used either individually or combined to reduce lumbar lordosis and or increase chest height to allow for shoulders to natural ly decend out of the plane of the cervical and tho...

Страница 10: ...trap is recommended during all procedures A patient saftey strap must be used during procedures where lateral roll function is used Directions for use 8 Directions for Use face rest platform adjustmen...

Страница 11: ...e face rest and rotate the facerest flat against the base frame This will protect the facerest support platform during transport When placing the Spine Positioning System in the bag put some pads wedg...

Страница 12: ...ch cervical procedures Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small Contoured Torso Wedge 1 7 x 12 Rectangular Adjuster Pad 1 8 Semi Round Bolster 1 Dir...

Страница 13: ...figured with two extra adjuster pads under the lumbar spine as a method to reduce lumbar lordosis and enhance comfort AP image of the lumbar spine Components used Platform Frame 1 Crescent Face Cushio...

Страница 14: ...e T1 2 interlaminar space Contralateral oblique showing the upper thoracic facet joints Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small Contoured Torso Wed...

Страница 15: ...age through the C1 2 segment Lateral image through the C1 3 segments Mary AP image through the C1 2 joints Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small...

Страница 16: ...n Right thoracic oblique image to visualize the trajectory for a transforaminal injection Contralateral oblique showing the trajectory for targeting the mid thoracic facet joint Components used Platfo...

Страница 17: ...ncluding the C7 T1 segment Directions for Use Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small Contoured Torso Wedge 1 7 x 12 Rectangular Adjuster Pad 1 8 x...

Страница 18: ...edures such as interlaminar epidural steroid injections facet injections medial branch blocks and medial branch radiofrequency neurotomy Components used Platform Frame 1 Crescent Face Cushion 1 Contou...

Страница 19: ...Virox Disinfecting All components may be disinfected using a 10 sodium hydrochlorite bleach solution Be sure to to remove excess solution and dry thoroughly All fabric covered components may be disinf...

Страница 20: ...d Replace any damaged or worn components Inspect face rest platform locking mechanism weekly Use the following procedure Step 1 Lock the platform cam Step 2 Rock platform up down Gently rock platform...

Страница 21: ...hanism is to simply put a thin piece of paper between the 2 pivot parts avoiding the pins and pull on the paper If the paper pulls out cam tightening is required Maintenance Cam tightening if required...

Страница 22: ...ame 1 EM2410 SP Crescent Face Cushion 1 0546 06 Contoured Torso Support Pad 1 0550 06 Small Contoured Torso Wedge 1 0554 06 Large Contoured Torso Wedge 1 4402 06 7 x 12 Rectangular Adjuster Pad 2 0552...

Страница 23: ...Pad 1 5 5 x 16 x 27 0550 06 Small Contoured Torso Wedge 1 2 5 x 16 x 23 0554 06 Large Contoured Torso Wedge 1 3 5 x 16 x 29 4402 06 7 x 12 Rectangular Adjuster Pad 2 1 x 7 x 12 0552 06 8 x 16 Rectangu...

Страница 24: ...rch 2010 Edition 2 May 2010 English Printed in U S A Contact Information Oakworks Medical 923 East Wellspring Road New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworksmed com European...