cautions

The cushioning foam contained within the Torso Support will lose its ability to 

spring back to the original position over time and the amount of foam compression will 

increase. Therefore, the Torso Support should be replaced periodically to ensure the 

device functions as intended. 

To prevent the potential of cross-contamination, it is strongly advised to use barrier tech-

niques when the device is in use. A disposable or laundered patient gown, or disposable pad 

are satisfactory for use as a barrier for the Torso Support and other components and acces-

sories, except when the patient presents with pathology that would indicate otherwise. A 

disposable face rest cover should be used to cover the Face Rest Cushion. Contact Oakworks 

for ordering information. Barrier techniques should be used in addition to disinfection procedures, 

not in lieu of them.

Be sure to support the weight of the patient’s head while making adjustments to the cervical  

positioning feature of the Platform Frame. Make sure all cam locks are secure before 

relinquishing support of the positioning assembly. 

The Cervical Support System (see page 5) has metal parts that can cause back scatter of x-rays. 

When x-rays are present, wear a suitable radiation barrier.

The Spine Positioning System is constructed using metal pins in the Quick Cam Locks and 

aluminum tubing in the support structure. These are out of the field of view in most A-P and 

oblique tilted views. Place the positioning assembly according to the recommendations in the 

directions for use to eliminate, or reduce any artifacts. If artifacts still remain to the extent that 

they would compromise the efficacy of needle placement, discontinue use of the device dur-

ing the affected procedure.

All materials used in the construction of the device and accessories are safe for  

temporary and moderately frequent human contact. The device is not intended  

for prolonged contact.

Do not use the Face Rest Support Arms as a handle to carry the Spine Positioning System.

Follow maintenance instructions found near the end of this manual. Mechanical components 

should be checked periodically to insure that they are functioning properly to insure the safety 

of the patient. 

 

C

au

Tions

caution

Содержание Spine Positioning System

Страница 1: ...so Support Pad 2 7 x 12 rectangular adjuster pads 2 8 x 16 rectangular adjuster pads 2 Contoured Torso Wedges pictured here with small wedge 1 Radiolucent frame with adjustable face rest 1 carry case...

Страница 2: ...t to change without notice and should not be construed as a commitment by Oakworks Inc Oakworks Inc assumes no responsibility for any errors that may appear in this document nor does it make expressed...

Страница 3: ...ns 2 3 Symbol Identification 4 Description of Components 5 7 Directions for Use 8 15 Maintenance Service 17 21 cleaning disinfecting 17 maintenance 18 19 list of parts 20 specifications 21 warranty 21...

Страница 4: ...omfort and imaging needs for all spinal column procedures WARNING warnings A patient safety strap is required during all procedures Follow normal and required safety protocol for all procedures where...

Страница 5: ...l cam locks are secure before relinquishing support of the positioning assembly The Cervical Support System see page 5 has metal parts that can cause back scatter of x rays When x rays are present wea...

Страница 6: ...mbol when used in this manual or on product labels indicates that the product should be protected from moisture The humidity specifications for Transport Storage are listed on page 23 This symbol when...

Страница 7: ...Crescent face rest pad One cam lock facilitates cervical flexion and extension 1 Crescent Face Rest Pad PN EM2410 SP 1 Contoured Torso Support Pad pn 0546 06 2 7 x 12 rectangular adjuster pads pn 4402...

Страница 8: ...enhance patient stability by reducing sway while in the device 0550 06 small CONTOURED Torso WEDGE 0554 06 large CONTOURED Torso WEDGE The Contoured Torso Wedge is constructed of dense foam and cover...

Страница 9: ...gular Adjuster pads are used either individually or combined to reduce lumbar lordosis and or increase chest height to allow for shoulders to natural ly decend out of the plane of the cervical and tho...

Страница 10: ...trap is recommended during all procedures A patient saftey strap must be used during procedures where lateral roll function is used Directions for use 8 Directions for Use face rest platform adjustmen...

Страница 11: ...e face rest and rotate the facerest flat against the base frame This will protect the facerest support platform during transport When placing the Spine Positioning System in the bag put some pads wedg...

Страница 12: ...ch cervical procedures Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small Contoured Torso Wedge 1 7 x 12 Rectangular Adjuster Pad 1 8 Semi Round Bolster 1 Dir...

Страница 13: ...figured with two extra adjuster pads under the lumbar spine as a method to reduce lumbar lordosis and enhance comfort AP image of the lumbar spine Components used Platform Frame 1 Crescent Face Cushio...

Страница 14: ...e T1 2 interlaminar space Contralateral oblique showing the upper thoracic facet joints Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small Contoured Torso Wed...

Страница 15: ...age through the C1 2 segment Lateral image through the C1 3 segments Mary AP image through the C1 2 joints Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small...

Страница 16: ...n Right thoracic oblique image to visualize the trajectory for a transforaminal injection Contralateral oblique showing the trajectory for targeting the mid thoracic facet joint Components used Platfo...

Страница 17: ...ncluding the C7 T1 segment Directions for Use Components used Platform Frame 1 Crescent Face Cushion 1 Contoured Torso Support Pad 1 Small Contoured Torso Wedge 1 7 x 12 Rectangular Adjuster Pad 1 8 x...

Страница 18: ...edures such as interlaminar epidural steroid injections facet injections medial branch blocks and medial branch radiofrequency neurotomy Components used Platform Frame 1 Crescent Face Cushion 1 Contou...

Страница 19: ...Virox Disinfecting All components may be disinfected using a 10 sodium hydrochlorite bleach solution Be sure to to remove excess solution and dry thoroughly All fabric covered components may be disinf...

Страница 20: ...d Replace any damaged or worn components Inspect face rest platform locking mechanism weekly Use the following procedure Step 1 Lock the platform cam Step 2 Rock platform up down Gently rock platform...

Страница 21: ...hanism is to simply put a thin piece of paper between the 2 pivot parts avoiding the pins and pull on the paper If the paper pulls out cam tightening is required Maintenance Cam tightening if required...

Страница 22: ...ame 1 EM2410 SP Crescent Face Cushion 1 0546 06 Contoured Torso Support Pad 1 0550 06 Small Contoured Torso Wedge 1 0554 06 Large Contoured Torso Wedge 1 4402 06 7 x 12 Rectangular Adjuster Pad 2 0552...

Страница 23: ...Pad 1 5 5 x 16 x 27 0550 06 Small Contoured Torso Wedge 1 2 5 x 16 x 23 0554 06 Large Contoured Torso Wedge 1 3 5 x 16 x 29 4402 06 7 x 12 Rectangular Adjuster Pad 2 1 x 7 x 12 0552 06 8 x 16 Rectangu...

Страница 24: ...rch 2010 Edition 2 May 2010 English Printed in U S A Contact Information Oakworks Medical 923 East Wellspring Road New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworksmed com European...

Отзывы: