Maximum Flow Temperature
-
82ºC
Electricity Supply
-
240V ~ 5OHz fused at 3A
Water Connections
Gravity Flow
- R
¾ (¾ in BSP Male)
Gravity Return to injector
‘Tee’
- To accept 28mm copper
Pumped Flow
- R.c.
3¾
(¾ in BSP Female)
Pumped Return using injector
‘Tee’
- To accept 22mm copper
Pumped Return without injector
‘Tee’ Gas supplyConnection - R. ¾ (¾ in BSP Male)
Gas supply Connection
-
R.c. ½
(½ in BSP Female)
Water Content
- 6.5 litres
- 1.43 gal
Appliance weight installed
- 56 kg
- 124 lbs
Appliance weight lift
- 50 kg
- 110 lbs
Page 7
TECHNICAL DATA - Page 8
BOILER
SIZE
INJECTOR
SIZE
GAS RATE
INPUT
OUTPUT
BURNERPRESSURE
m3/h
(ft3/h)
kW
(Btu/h)
kW
(Btu/h)
mbar
in wg
Min
3.1 mm
0.75
(26.57)
8.06
(27500) 5.86
(20000)
3.9
1.6
20/35
1.02
(35.94)
10.9
(37200) 8.06
(27500)
7.5
3.0
Max
1.26
(44.44) 13.48 (46000) 10.26 (35000)
11.0
4.4
Min
3.5mm
1.31
(46.37) 14.07 (48000) 10.26 (35000)
7.5
3.0
35/50
1.56
(55.00) 16.70 (57000) 12.46 (42500)
10.2
4.1
Max
1.79
(63.29) 19.20 (65500) 14.65 (50000)
13.5
5.4
Содержание CF 20/35
Страница 4: ......
Страница 5: ...Page 4 INSTALLATION DATA Page 5 FIG 2 GENERAL ARRANGEMENT...
Страница 6: ...Page 5...
Страница 17: ...FIG 4 OPEN VENTED FULLY PUMPED SYSTEM FITTED WITH A COMBIN ED FEED AND VENT Page 10 TECHNICAL DATA Page 11...
Страница 18: ...FIG 5 FULLY PUMPED SEALED SYSTEM FIG 6 OPEN VENTED GRAVITY DOMESTIC HOT WATER AND PUMPED CENTRAL HEATING SYSTEM...
Страница 43: ...Page 25...