2.7.3 Output Mode
1
0
PTLH
Low/ High_IR_ CARRY
IRSEL
PAD
Output Mode Configuration
User can select output mode to supply both normal drive current and normal/large/constant sink current
by setting related mask options. But drive current of NY6 is always weaker than normal sink current,
about half the scale.
2.7.4 I/O Pin Mask Option
This Section will describe the summary of available functionalities for each I/O pin. All functionalities are
determined by setting of corresponding mask options.
Category
I/O pin
Option
NY6A
PA0
PA1
Input with pull-high, floating or register-controlled pull-high.
Normal, large or constant current output.
PA2/IR
IR carrier output or Normal I/O.
Input with pull-high, floating or register-controlled pull-high.
Normal, large or constant current output.
PA3/Reset
Reset input or Normal I/O.
Input with pull-high, floating or register-controlled pull-high.
Normal, large or constant current output.
PBx
Normal I/O
Input with pull-high, floating or register-controlled pull-high.
Normal, large or constant current output.
All I/O
Weak or strong input pull-high resistor.
NY6B
PA0/VIP
PA1/VIN
Comparator input or Normal I/O.
Input with pull-high, floating or register-controlled pull-high.
Normal, large or constant current output.
PA2/IR
IR carrier output or Normal I/O.
Input with pull-high, floating or register-controlled pull-high.
Normal, large or constant current output.