NXP Semiconductors
UM11192
User Manual for LPCXpresso54S018M Development Board
UM11192
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2019. All rights reserved.
User manual
Rev. 1.0
— 13th February 2019
9 of 34
Circuit Ref
Description
Section
D14
Target power
This LED illuminates when the 3.3V supply to the LPC54S018J4M is
present.
n/a
D15
Reset LED
This LED illuminates when reset is asserted either via the expansion
connector or when reset button SW1 is pressed.
n/a
SW1
Reset button
Press and release this button to reset the LPC546x8/540xx. Note that
this does not reset the Link2 Debug Probe.