7.1 Creating and using a register configuration file
Creating an Excel register configuration file allows the user to initialize the evaluation
board MCU with a predefined set of register values. To create a register configuration
file, do the following:
1. Open a new Excel spreadsheet file and label the first three columns in row 1
hex
,
registers
and
comment
. Notice that the first two columns —
hex
and
registers
— are
mandatory. The
comment
column is optional.
2. In the
hex
column (column A), enter the data or address to be assigned to each
register. The address and data must be contained in two bytes and must be
expressed as a hexadecimal value. Enter one row per register.
3. In the
registers
column (column B), enter the register name associated with the value
in the
hex
column.
4. In the
comments
column (column C), enter any comments desired. Data in this
column is not processed by the FlexGUI. The image below illustrates a typical register
configuration file.
Mandatory
Optional
aaa-025557
5. Launch FlexGUI. When FlexGUI opens, click the
Load Sequence
button to load the
register configuration file.