Nu-Link-Gang
Dec. 23, 2019
Page
26
of 37
Rev 1.00
NU
-LINK
-GA
NG
USE
R MA
NU
AL
5.1.2 Waveform
1.
The Nu-Link-Gang power on. STARTx, BUSYx, PASSx, and FAILx are set to logic 1.
2.
To start programming, STARTx needs to be set to logic 0 for TSTART,
.
3.
Programming start-up. BUSYx is set to logic 0 , and might toggle during programming.
4.
When finish programming, BUSYx is set to logic 1, and PASSx or FAILx is set to logic 0.
When BUSYx
is set to logic 1, and PASSx is set to logic 0, means “PASS”.
When BUSYx is set to logic 1, and FAILx
is set to logic 0, means “FAIL”.
STARTx
BUSYx
PASSx
FAILx
T
START
Figure 5-2 PASS Waveform
STARTx
BUSYx
PASSx
FAILx
T
START
Figure 5-3 FAIL Waveform