M451
May. 4, 2018
Page
964
of
1006
Rev.2.08
M4
51
S
E
RI
E
S
T
E
CH
NICA
L RE
F
E
R
E
NC
E
M
A
NU
A
L
Bits
Description
[7:3]
CMPSPL
Compare Sample Module Selection
00000 = Sample Module 0 conversion result EADC_DAT0 is selected to be compared.
00001 = Sample Module 1 conversion result EADC_DAT1 is selected to be compared.
00010 = Sample Module 2 conversion result EADC_DAT2 is selected to be compared.
00011 = Sample Module 3 conversion result EADC_DAT3 is selected to be compared.
00100 = Sample Module 4 conversion result EADC_DAT4 is selected to be compared.
00101 = Sample Module 5 conversion result EADC_DAT5 is selected to be compared.
00110 = Sample Module 6 conversion result EADC_DAT6 is selected to be compared.
00111 = Sample Module 7 conversion result EADC_DAT7 is selected to be compared.
01000 = Sample Module 8 conversion result EADC_DAT8 is selected to be compared.
01001 = Sample Module 9 conversion result EADC_DAT9 is selected to be compared.
01010 = Sample Module 10 conversion result EADC_DAT10 is selected to be compared.
01011 = Sample Module 11 conversion result EADC_DAT11 is selected to be compared.
01100 = Sample Module 12 conversion result EADC_DAT12 is selected to be compared.
01101 = Sample Module 13 conversion result EADC_DAT13 is selected to be compared.
01110 = Sample Module 14 conversion result EADC_DAT14 is selected to be compared.
01111 = Sample Module 15 conversion result EADC_DAT15 is selected to be compared.
10000 = Sample Module 16 conversion result EADC_DAT16 is selected to be compared.
10001 = Sample Module 17 conversion result EADC_DAT17 is selected to be compared.
10010 = Sample Module 18 conversion result EADC_DAT18 is selected to be compared.
[2]
CMPCOND
Compare Condition
0= Set the compare condition as that when a 12-bit A/D conversion result is less than the
12-bit CMPDAT (EADC_CMPn [27:16]), the internal match counter will increase one.
1= Set the compare condition as that when a 12-bit A/D conversion result is greater or
equal to the 12-bit CMPDAT (EADC_CMPn [27:16]), the internal match counter will
increase one.
Note:
When the internal counter reaches the value to (CMPMCNT (EADC_CMPn[11:8],
n=0~3) +1), the CMPF bit will be set.
[1]
ADCMPIE
A/D Result Compare Interrupt Enable Bit
0 = Compare function interrupt Disabled.
1 = Compare function interrupt Enabled.
If the compare function is enabled and the compare condition matches the setting of
CMPCOND (EADC_CMPn[2], n=0~3) and CMPMCNT (EADC_CMPn[11:8], n=0~3),
ADCMPFn (EADC_STATUS2[7:4], n=0~3) will be asserted, in the meanwhile, if
ADCMPIE is set to 1, a compare interrupt request is generated.
[0]
ADCMPEN
A/D Result Compare Enable Bit
0 = Compare Disabled.
1 = Compare Enabled.
Set this bit to 1 to enable compare CMPDAT (EADC_CMPn[27:16], n=0~3) with specified
sample module conversion result when converted data is loaded into EADC_DAT register.
Содержание ARM Cortex NuMicro M451 Series
Страница 301: ...M451 May 4 2018 Page 301 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL...
Страница 324: ...M451 May 4 2018 Page 324 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL Figure 6 4 18 Checksum Calculation Flow...
Страница 355: ...M451 May 4 2018 Page 355 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL 2 0 Reserved Reserved...
Страница 625: ...M451 May 4 2018 Page 625 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL 00 5 bits 01 6 bits 10 7 bits 11 8 bits...
Страница 721: ...M451 May 4 2018 Page 721 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL the SCL line 1 0 Reserved Reserved...
Страница 1001: ...M451 May 4 2018 Page 1001 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL LQFP 64L 10x10x1 4 mm footprint 2 0 mm 9 2...
Страница 1002: ...M451 May 4 2018 Page 1002 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL LQFP 64L 7x7x1 4 mm footprint 2 0 mm 9 3...
Страница 1003: ...M451 May 4 2018 Page 1003 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL LQFP 48L 7x7x1 4mm footprint 2 0mm 9 4...