M451
May. 4, 2018
Page
601
of
1006
Rev.2.08
M4
51
S
E
RI
E
S
T
E
CH
NICA
L RE
F
E
R
E
NC
E
M
A
NU
A
L
UART Auto-Flow Control Function
The UART supports auto-flow control function that uses two signals, nCTS (clear-to-send) and
nRTS (request-to-send), to control the flow of data transfer between the UART and external
devices (e.g. Modem). When auto-flow is enabled, the UART is not allowed to receive data until
the UART asserts nRTS to external device. When the number of bytes stored in the RX FIFO
equals the value of RTSTRGLV (UART_FIFO [19:16]), the nRTS is de-asserted. The UART
sends data out when UART detects nCTS is asserted from external device. If the valid asserted
nCTS is not detected, the UART will not send data out.
APB BUS
RX FIFO
TX FIFO
Flow Control
Serial to Parallel
Serial to Parallel
UART_nCTS
UART_RX
UART_nRTS
UART_TX
Figure 6.13-8 Auto-Flow Control Block Diagram
The Figure 6.13-9 demonstrates the nCTS auto-flow control of UART function mode. User must
set ATOCTSEN (UART_INTEN [13]) to enable nCTS auto-flow control function. The CTSACTLV
(UART_MODEMSTS [8]) can set nCTS pin input active state. The CTSDETF
(UART_MODEMSTS[0]) is set when any state change of nCTS pin input has occurred, and then
TX data will be automatically transmitted from TX FIFO.
Содержание ARM Cortex NuMicro M451 Series
Страница 301: ...M451 May 4 2018 Page 301 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL...
Страница 324: ...M451 May 4 2018 Page 324 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL Figure 6 4 18 Checksum Calculation Flow...
Страница 355: ...M451 May 4 2018 Page 355 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL 2 0 Reserved Reserved...
Страница 625: ...M451 May 4 2018 Page 625 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL 00 5 bits 01 6 bits 10 7 bits 11 8 bits...
Страница 721: ...M451 May 4 2018 Page 721 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL the SCL line 1 0 Reserved Reserved...
Страница 1001: ...M451 May 4 2018 Page 1001 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL LQFP 64L 10x10x1 4 mm footprint 2 0 mm 9 2...
Страница 1002: ...M451 May 4 2018 Page 1002 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL LQFP 64L 7x7x1 4 mm footprint 2 0 mm 9 3...
Страница 1003: ...M451 May 4 2018 Page 1003 of 1006 Rev 2 08 M451 SERIES TECHNICAL REFERENCE MANUAL LQFP 48L 7x7x1 4mm footprint 2 0mm 9 4...