background image

ENGLISH

Danger
Exposure to extremely high noise levels may cause a permanent 
hearing loss. Individuals vary considerably to noise induced hearing 
loss but nearly everyone will lose some hearing if exposed to sufficiently 
intense noise for a sufficient time. The U.S. Government's 
Occupational Safety and Health Administration (OSHA) has specified 
the following permissible noise level exposures: 

According to OSHA, any exposure in the above permissible limits could 
result in some hearing loss. Ear plugs or protectors in the ear canal or over 
the ears must be worn when operating this amplification system in order to 
prevent a permanent hearing loss. If exposure in excess of the limits as 
put forth above, to insure against potentially harmful exposure to high 
sound pressure levels, it is recommended that all persons exposed to 
equipment capable of inducing high sound pressure levels, such as this 
amplification system, be protected by hearing protectors while this unit is in 
operation.

DURATION PER DAY (HOURS)    8    6    4    3    2     1

SOUND LEVEL (dB)                       90  93   95  97 100  103

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE 
OF NON-INSULATED  "DANGEROUS VOLTAGE" WITHIN THE 
PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE 
TO CONSTITUTE  A RISK OF ELECTRIC SHOCK TO PERSONS.

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE 
OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) 
INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT.

1.  Read all safety and operating instructions before using this 

product.

2.  All safety and operating instructions should be kept for future 

reference.

3.

Read and understand all warnings listed on the operating 

instructions.

4 . Follow all operating instructions to operate this product.

5.  This product should not be used near water, i.e. bathtub, sink, 

swimming pool, wet basement, etc.

6.  Only use dry cloth to clean this product.

7.  Do not block any ventilation openings, It should not be placed flat 

against a wall or placed in a built-in enclosure that will impede the 
flow of cooling air.

8.

 Do not install this product near any heat sources ; such as, 

radiators, heat registers, stove or other apparatus (including heat 
producing amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-

type plug. A polarized plug has two blades with one wider than the 
other. A grounding-type plug has two blades and a third grounding 
prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

10. Protect the power cord being walked on or pinched, particularly at 

plugs, convenience receptacles and the point where they exit 
from the apparatus. Do not break the ground pin of the power 
supply cord.

11 . Only use attachments specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, or table specified by 

the manufacturer or sold with the apparatus. When a cart is used, 
use caution when moving cart/apparatus combination to avoid 
injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for 

long periods of time.

14. Care should be taken so that objects do not fall and liquids are 

not spilled into the unit through the ventilation ports or any other 
openings.

15. Refer all servicing to qualified service personnel. Servicing is 

required when the apparatus has been damaged in any way; 
such as, power-supply cord or plug is damaged, liquid has been 
spilled or objects have fallen into the apparatus, the apparatus 
has been exposed to rain or moisture, does not operate normally 
or has been dropped.

16. WARNING: To reduce the risk of fire or electric shock, do not 

expose this apparatus to rain or moisture.

IMPORTANT SAFETY INSTRUCTIONS

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

 TO REDUCE THE RISK OF ELECTRIC SHOCK, DO 

NOT REMOVE CHASSIS. NO USER-SERVICEABLE 
PARTS INSIDE. REFER SERVICING TO QUALIFIED 
SERVICE PERSONNEL.

AVIS:   RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.

CAUTION

APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING 
AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, 
SHALL BE PLACED ON THE APPARATUS.

1

Содержание NV-LRC1

Страница 1: ...EssentiaTM NV E6D UK Installation Manual...

Страница 2: ......

Страница 3: ...losure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that p...

Страница 4: ...s d eau comme par exemple baignoires viers piscine sous sol humides Etc 6 Utiliser exclusivement un chiffon sec pour nettoyer ce produit 7 Ne bloqu r aucune ouverture de ventilation Ne pas placer le...

Страница 5: ...mplifier Page 10 VII Connecting the IR Emitters Page 10 VIII Expanding Essentia to 12 Zones Page 11 IX Installing the Essentia Keypads Page 11 X Keypad Zone Settings Page 12 Zone EQ Control and Source...

Страница 6: ...e Enjoying quality audio throughout the home is simple and affordable with Essentia This installation manual is designed to provide a sequential step by step guide to making full use of the many featu...

Страница 7: ...USE NV SLC1 CABLE 1 2 3 4 5 6 1 2 3 4 5 6 OUTPUT POWER OUTPUT POWER OUTPUT POWER OUTPUT POWER OUTPUT POWER OUTPUT POWER 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 VARIABL...

Страница 8: ...zone is currently turned on Keypad Features 1 Volume Level The level of the zone volume is indicated by these LEDs light emitting diodes 2 Power The power button turns that keypad s zone on and off in...

Страница 9: ...the system when the phone or doorbell rings 10 Network Input This RJ45 connection is the input for all zone information coming from the Essentia keypads The connection is made using the Network Cable...

Страница 10: ...rce specific volume control such as a TV or stereo receiver This is not used for NuVo zone volume 6 Numeric Buttons These buttons provide source specific direct numeric access 7 Power Button This powe...

Страница 11: ...em out individually Arrange the wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their correct order and trim them evenly across the top Most crimp tools have a wire trimme...

Страница 12: ...housing the home audio video equipment The amplifier should be plugged in and the power button on the front panel should be turned on before proceeding with the rest of the installation This activates...

Страница 13: ...UT POWER 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 VARIABLE OUTPUT VARIABLE OUTPUT VARIABLE OUTPUT FIXED OUTPUT FIXED OUTPUT FIXED OUTPUT TIP L RING R TIP L RING R TIP L RING R Source 1 Tuner 1 Audio Out VI...

Страница 14: ...nstalling the Essentia Keypads You are now ready to install the keypads and complete the Essentia installation This is easily done using a rotary switch located on the back of the keypad to set a spec...

Страница 15: ...e Down disables the group function and causes the keypad to operate independently of all other groups fig 11 FLAT 4 dB 4 dB 6 dB 8 dB 6 dB 8 dB Fig 10 Fig 11 X Keypad Zone Settings Each Essentia keypa...

Страница 16: ...c e c h a n g i n g a l o c a l z o n e s v o l u m e c o n t r o l o r b y t u r n i n g a l o c a l z o n e s k e y p a d o f f a n d b a c k o n T h e M a s t e r M o d e i s t u r n e d o f f b y...

Страница 17: ...N OFF SWITCH AUDIO AC DC POWER MODE OUTPUT POWER 8 OHM 70W X 2 4 OHM 100W X 2 CONTROL USE ONLY WITH 250V FUSE The Zone keypad controls the audio volume Diagram shown using the NuVo P2100 amplifier Sou...

Страница 18: ...g the NuVo P2100 amplifier Source 1 Tuner 1 Audio Out Zone Room 1 ZONE 6 SYSTEM ZONE TRIGGER OUTPUTS SOURCE LINK SOURCE INPUTS ZONE 1 NETWORK EMITTER OUTPUTS DIGITAL LINK ZONE 3 ZONE 4 ZONE 5 ZONE 2 P...

Страница 19: ...VARIABLE OUTPUT FIXED OUTPUT SUM1 3033118 C US CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV 6DM SIX SOURCE SIX ZONE...

Страница 20: ...r of the LSA40 is automatically engaged LSA40P Back LSA40P Front Zone Room 1 Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier NuVo System zone speakers 50 Watt AC power ada...

Страница 21: ...R DESIGNED IN USA 28VDC 5A ZONE 1 MADE IN CHINA RTE TE K I N 3033118 RT E E T K N I CM ZONE 3 ZONE 2 ZONE 4 POWER LSA40PD Front LSA40PD Back 200 Watt AC power adapter included with the LSA40PD AC Powe...

Страница 22: ...Four conductor speaker wire from the LSI12 to the zone speakers Speaker input from Essentia or Simplese LSI12 front LSI12 back ZONE 6 SYSTEM ZONE TRIGGER OUTPUTS SOURCE LINK SOURCE INPUTS ZONE 1 NETW...

Страница 23: ...on the Essentia to the Voltage Trigger on the P2100 Fig 22 R L SENSITIVITY OdBV 1 0RMS 12 6 0 LEFT 6 12 RIGHT 0 AUDIO INPUT 2 INPUT OUTPUT CONTROL VOLTAGE TRIGGER 3 30 VOLTS AC OR DC ON OFF SWITCH AUD...

Страница 24: ...e and prevent any functionality When locked the keypad will simply flash when a function is attempted Pressing and holding the source button again will unlock the keypad All the keypads change when a...

Страница 25: ...Listing CAN CSA E60065 00 Source Inputs 1 6 CE Listing SEMKO EN60065 EN55013 input Impedance 10K EN55020 EN6100 3 2 EN6100 3 3 A1 Input Sensitivity for rated power 300mV RMS Input Overload 3V RMS Phys...

Страница 26: ...etailed in the owner s manual If no keypad is connected with a given zone address then ZoneSet will default to A OR0 No override B BASS 0 Bass FLAT C TREB 0 Treble FLAT D GRP0 SOURCE GROUPING OFF E VR...

Страница 27: ...is ON 1if SOURCE GROUP is OFF yy level below max in dB 00 to 78 dB include lead 0 for all single digit values yy MT if in MUTE state yy XM if external MUTE is being held active zzz MST if this zone is...

Страница 28: ...system will restore keypad permanent settings see the User Manual for details on how to perform these settings b an operator manually sets one of these parameters from a keypad This takes the unit out...

Страница 29: ...N CR COMMAND ALLMOFF CR ALL MUTE OFF RESPONSE ALLMOFF CR COMMAND ZxxSRCp CR Switch zone xx to SOURCE p 1 to 6 RESPONSE Same response as for ZxxCONSR CR COMMAND ZxxVOLyy CR Set volume of zone xx to lev...

Страница 30: ...response as for ZxxSETSR CR NOTE sending this command to the E6D will override the non volatile GROUP setting set from keypad for this zone until power is cycled COMMAND ZxxGRPOFF CR zone xx SOURCE G...

Страница 31: ...x is the major version number and yy is the minor version number RESPONSE EXTMON CR Issued whenever the External MUTE first activates closure to ground and 0 whenever the External MUTE de activates o...

Страница 32: ...0730...