47 | FULL HD Network Video Recorder
4.4
Alarm
4.4.1 Sensor
Users can select the sensor input between NVR and supported network cameras. Mapping is only available for either
the Network camera sensor or the local sensor of the NVR on the same channel.
Type
OFF, N/O (Normal Open) , N/C (Normal Close)
Cam
Select the associated camera channel.
Notify
Users can select how to be alerted when a sensor is activated by pressing the
“NOTIFY” button. The system can
generate a buzzer sound and/or make a pop-up screen for the camera in alarm.
Preset
Users can select the camera to move to a preset position, once the sensor is triggered. (User should setup a
preset position in the PTZ menu 4.2.3 in advance)
In addition, users can set multi-preset with a single PTZ
camera. Therefore, users can cover a multi-preset zone with a single PTZ camera.
C
AUTION
Relay contact can handle up to 24VDC/1A(or 125VAC/0.5A) of other devices. If connected to a circuit
that is over 24VDC/1A(or 125VAC/0.5A), the system may experience problems.
Relay