Nuvap N2Health Manual 

Ver 1.7 

 

 

Wait for the light guide on the top of the device (see the picture) to switch on. 
When the blue light turns on, open the application on the mobile device and 
select the item "add device" from the "Device Management" menu. (Attention: If 
the indicator light emits a green light, perform the "Reset" procedure. When the 
indicator is red, contact Nuvap technical support). 

 

 

The application will guide the user through the configuration procedure. At the end, a green light signal will 
be emitted. If the procedure is not successful, the light signal will be yellow. In this case, consult the 
“Sound and light signals” section of this manual. 

 

6.

 

Device Reset 

To be configured, the device must be in "waiting for configuration" state. If it is not (or if it is necessary to 
change the parameters of the WiFi network), it is necessary to reset the device through the following 
procedure: 

-

 

If already powered, turn the device off and on again using the power button 

-

 

Wait 2 minutes for the device to activate the features 

 

 

-

 

With the palm of your hand, press the touch button and keep 
it pressed for 15 seconds (picture). 

-

 

When the blue light guide is turned on, release the touch 
button. 

-

 

When the light guide flashes blue, it shows that it is in the 
“configuration waiting” state. To avoid inadvertent resets, this 
option is automatically disabled 1 hour after switching on. 

 

7.

 

Sound and light notifications 

Light notification: 

-

 

blue light flashing every 5 seconds: waiting for user device configuration 

-

 

green light on for 2 seconds: device configuration notification 

-

 

green light turns on for 0.5 seconds: start of measurement cycle 

-

 

yellow light flashing for 0.5 seconds: generic error and / or no connection to the internet. Check the 
correct functioning of the WiFi hotspot or SIM mobile network 

-

 

5 yellow light flashes of 0.5 seconds each: wrong WiFi network password, re-configure the device 

-

 

Red light: fatal error, contact Nuvap support 

 

Содержание N2Health ProSystem Series

Страница 1: ...Nuvap N2Health Manual Ver 1 7 1 Nuvap N2Health ProSystem Series User Manual...

Страница 2: ...on 3 2 Device 3 3 Nuvap platform and smartphone application 4 4 Device installation 5 5 Device configuration 5 6 Device Reset 6 7 Sound and light emissions 6 8 Maintenance 7 9 Disposal 7 10 Certificat...

Страница 3: ...alculation based on Nuvap algorithms to build the synthetic Nuvap Index indicator The Nuvap Index allows to identify the level of healthiness of the environment in which the device is placed with a va...

Страница 4: ...uvap services and devices by the ProSystem solution s users The platform provides the following main services Device management User management Collection and elaboration of the sensors data Value add...

Страница 5: ...hentication password The device supports the types of WiFi networks indicated in the The Device section of this manual Configuration with mobile connectivity the SIM is supplied pre installed by Nuvap...

Страница 6: ...ough the following procedure If already powered turn the device off and on again using the power button Wait 2 minutes for the device to activate the features With the palm of your hand press the touc...

Страница 7: ...to your sales representative for more information about this service For each device the calibration certificate issued by the manufacturer may be requested by sending an email to support nuvap com i...

Страница 8: ...EU It is stated that the following standards and or specifications have been applied IEC 61010 1 2010 e EN 61010 1 2010 EN 61326 1 2013 ETSI EN 301 489 1 V2 1 1 ETSI EN 301 489 17 V3 1 1 ETSI EN 300 3...

Страница 9: ...k via the supplied AC DC power supply It must be used in environments with temperatures between 5 C 25 f and 40 c 105 f It has been designed to be used indoors at work or in residential areas it is no...

Отзывы: