7.0 High Pressure Compressor Technical Data
Capacity and Power Consumption:
•
Normal working pressure – 3600 psi (250 bar)
•
FAD Flow 9.3CFM (265 L/min)
•
Charging Rate – 10.8 SCFM (307 L/min)
•
Compressor speed of rotation – 1550 rpm
•
Maximum working pressure – 5000 psi (354 bar)
•
Transmission – Belt drive
Cooling:
•
Allowed ambient temperature – 32-105°F (0-40°C)
•
Air Cooled Interstage & Aftercooler
Motor and Electrical Values:
Single Phase Motor
•
Motor - 7.5hp Single phase
•
Speed of rotation – 3450 RPM
•
Compressor current
35 amps @ 230 V / 60 Hz
Three-Phase Motor
•
Motor - 7.5hp Three-phase
•
Speed of rotation – 3450 rpm
•
Compressor current
25 amps @ 230 V / 60 Hz
10.5 amps @ 380 V / 50 Hz
11 amps @ 460 V / 60 Hz
General Technical Data:
•
Number Of Stages - 3
•
Number Of Cylinders – 3
•
Lubrication – Splash Lubricated
•
Oil Quantity – 1.6 qt. (1.5 L)
•
HP Filtration Rating – CGA Grade E, 30,000 cu ft at 68
o
F (20
o
C)
•
Condensate Drains – Automatic & Manual Interstage & Final
•
Fill Pressure Stop – Automatic & Manual
•
Low Oil Level Shutdown
•
High Temperature Shutdown
•
Interstage Pressure Gauges