Changing LP Filtration Elements
Change Filter Elements every 250 hours. If the Nitrox System is operated in high humidity
and/or high temperature, Filter Elements must be changed more often. See Appendix for
details on Filter Element Life Factors. Visual service indicators on the HF series filters
assist with monitoring replacement intervals.
1) Push up on Filter Bowl, rotate counter-clockwise, and lower to remove.
2) Gently unscrew Filter Element and pull down off mounting post.
3) Replace Element and reassemble in reverse order.
The interior of the Filter Bowls can be cleaned with a diluted solution of Simple Green
TM
and
flushed thoroughly with clean water. This will assist to prolong the life of the element, bowl,
and auto drain.
Housing
Element inside bowl
Bowl