12. System Flow Chart
LP Aftercooler Removes
Moisture
LP Feed Air Filtration
Produces Grade D Air
BP Regulator Controls the
amount of Feed Air
pumped by the compressor
Moisture Separator in Drier
removes moisture
Thermostat Controlled Heater
Heats Air to 110ºF (43ºC)
Membrane Separates Supply
Air Into Permeate and
Nitrogen Rich Gas
Permeate Exits Membrane
Containing 43-44% O
2
Nitrogen Rich Gas Exits
Through Fixed Orifice
located in exhaust cooling
air vent
Mixing Tube Mixes Air &
Permeate to Create Nitrox
Containing 24-40% O
2
Air Intake Delivers Filtered
Ambient Air to Mixing Tube
Permeate O
2
Analyzer
Monitors Nitrox before
Compression to +/- 2% O
2
HP Compressor with
Moisture Removal &
Filtration Compresses Nitrox
Fill O
2
Analyzer Monitors
Nitrox Mixture to +/- 1% O
2
HP Nitrox Delivered to
Storage
HP Nitrox Delivered to
Scuba Cylinder
- OR -
Optional Vacuum Pump or
Blower
LP Compressor Produces LP
Feed Air
Refrigerated Air Drier cools
the air
Voyager II Nitrox System
Components Shown Within
Dashed Lines