background image

4

PART

REF.

NUMBER

PART DESCRIPTION

1

97009334

Housing

2

99390015

Grounding Clip

3

99030190

Fan Delay

4

98006989

Element Bracket (2 Required)

5

99271155

Heating Element (Model 9192NT)

99270723

Heating Element (Model 9194NT)

99270724

Heating Element (Model 9198NT)

6

99400061

Bushing

7

97008688

Black Wire Assembly (29–1/2")

8

97008690

Black Jumper Wire

9

*

Thermal Overload Bracket

10

*

Thermal Overload

11

97008692

Red Power Wire

12

99150491

Screw, 8–18 x 3/8 Ph. Pan Head

(14 Required)

13

97008683

Partition Plate Assembly

14

93270619

Wire Clamp ( 3 Required)

15

99260425

Nut, 8–32 Hex Keps (2 Required)

20

99160350

Screw, 6–32 x 1/4 Ph. Pan Head

(2 Required)

21

99030324

Thermostat

22

99080251

Motor (Model 9198NT)

23

99080249

Motor (Models 9192NT & 9194NT)

24

99020255

Fan Blade

25

97013822

Grille

26

99150478

Screw, 8–18 x 3/8 PH Truss Hd.

(4 Required)

27

99091017

Grille Logo

29

99360136

Knob

30

99110687

Security Cover

31

93150462

Screw, 8–18 x 5/8 Oval Head (2 Required)

*

97013945

Assembly, Thermal Overload (Includes Key

Nos. 9, 10, & 12 (2))

PARTS LIST

NUTONE ONE YEAR LIMITED WARRANTY

NuTone warrants to the original consumer purchaser of our products
that such products will be free from defects in materials or workman-
ship for a period of one year from date of original purchase. THERE
ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, IN-
CLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, NuTone will, at our option, repair or
replace, without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have
been subject to misuse, negligence, accident, improper maintenance
or repair (other than by us), faulty installation or installation contrary
to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period
as specified for the express warranty. Some states do not allow
limitation on how long an implied warranty lasts, so the above limita-
tion may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT OUR
OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. nutone SHALL NOT BE LI-
ABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAM-
AGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above
limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have
other rights, which vary from state to state. This warranty super-
sedes all prior warranties.
To qualify for warranty service, you must (a) notify us at the address
or telephone number below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product
or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.

NuTone, Inc.

4820 Red Bank Road

Cincinnati, OH 45227

(1-800-543-8687)

WARRANTY

Product specifications

subject to change

without notice.

4820 Red Bank Road

Cincinnati, Ohio 45227

Printed in U.S.A., 3/03

Part No. 99043274A

Содержание 9192NT

Страница 1: ...nced impellers keep drywall spray construction dust etc off power unit 7 Please read specification label on product for further informa tion and requirement INSTALLATION INSTRUCTIONS READ SAVE THESE INSTRUCTIONS Wall Heater MODELS 9192NT 9194NT 9198NT FIGURE 1 PLAN THE INSTALLATION This heater is intended to be used to supply supplemental heat from a wall location in new or existing construction C...

Страница 2: ...s wired direct use the built in thermostat for tempera ture control OPTIONAL WIRING CONVERSIONS When using a separate wall control simply turn the heater s built in thermostat to its highest setting There is no need to disconnect the built in thermostat a Turn built in thermostat to highest setting b Remove knob c Fasten security cover to grille LINE VOLTAGE THERMOSTAT Refer to FIGURE 7 If wall mo...

Страница 3: ...until the element is hot Likewise it keeps the fan running until the element cools down USE AND CARE CAUTION DISCONNECT POWER AT SERVICE ENTRANCE AND LOCK OUT PANEL BEFORE CLEANING OR SERVICING UNIT Thermal Overload Protector Your heater is equipped with a manual reset thermal overload pro tector If heater fails to operate when thermostat is turned to its highest setting 1 Turn off power at servic...

Страница 4: ...found to be defective under normal use and service THISWARRANTYDOESNOTEXTENDTOFLUORESCENTLAMP STARTERSAND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by us faulty installation or installation contrary to recommended installation instructions The duratio...

Страница 5: ... unidad de energía alejada de rocíos de yeso polvo de construcción etc 7 Para más información y requisitos lea la etiqueta de especificación sobre el producto INSTRUCCIONES DE INSTALACIÓN LEA Y CONSERVE ESTAS INSTRUCCIONES Calentador de la Pared MODELOS 9192NT 9194NT 9198NT PLANIFICACION DE INSTALACIÓN Este calentador ha sido diseñado para proporcionar calefacción adicional desde el cielo raso en ...

Страница 6: ...ado para el control de temperatura CONVERSIONES DE CABLEADO OPCIONAL Al usar un control de pared separado prenda el termostato incorporado al calentador en su graduación más alta No es necesario desconectar el termostato incorporado Para evitar un ajuste descendente no deseado del termostato incorporado a Ponga el termostato incorporado en su graduación más alta b Quite la perilla c Fije la cubier...

Страница 7: ... EL PANEL ANTES DE LIMPIAR O DAR SERVICIO A LA UNIDAD Protector de sobrecarga termica Su calentador cuenta con un protector de sobrecarga térmica de reposición manual Si el calentador no funciona cuando el termostato está activado en su graduación más alta 1 Corte la energía en la entrada de servicio 2 Saque la perilla y la rejilla 3 Oprima el botón RESET Este tipo de dispositivo es especialmente ...

Страница 8: ...re defectuosa bajo condiciones normales de servicio y uso ESTAGARANTIANOSEAPLICAATUBOSYARRANCADORESDE LAMPARAS FLUORESCENTES Esta garantía no cubre a mantenimiento y servicio normales ni b cualquier producto o piezas que hayan sido utilizadas de forma errónea negligente que hayan tenido un accidente o que hayan sido reparadas o mantenidas incorrectamente por otras compañías que no sean NuTone inst...

Отзывы: