Operating Instruction and Documentation
UNI-LIFT 3500 NT ND/ UNI-LIFT 3200 NT Plus ND
- 39 -
9. Handing over and Initiation
9.1 Installation Regulations
• The installation of the lift is performed by trained technicians of the manufacturer or one of its
distribution partners. If the operator can provide trained mechanics, he or she can install the
lift by him or herself. The installation has to be done according to this regulation.
• Installing the standard-automotive lift in a hazardous location or a washing bay is not
allowed.
• Before installation a sufficient foundation must be constructed. If the foundation is already
constructed then proof that the foundation conforms to the standard is required.
A level foundation for the installation is required. The foundations must be based in a frost
resistance depth, both outdoors and indoors in a position where the installer believes there is
no chance of frost.
• An electrical supply 3~/N+PE, 400 V, 50 Hz must be provided.
The supply line must be protected with a time-lag fuse T16A (VDE0100 German regulation).
The minimum diameter amounts to 2.5 mm².
• All cable ducts must be equipped with protective coverings to prevent accidents.
• After assembly of the lift, the protective grounding of the lift must be examined after
International Electronical Commission (IEC) guidelines (60364-6-61) before first start-up by
operators. Also an insulation resistance examination is recommended.
9.2 Installation of the lift
• Install the lift according to the data sheet and the foundation plan.
• Install the operating unit at its designed place. Connect the power supply.
• Connect the hydraulic. All hoses are marked.
• Fill in the hydraulic oil, approx. 14 litres are needed. A high quality hydraulic oil is
recommended, it should be 32 cst. (e.g. HLP 32 LTD. OEST Company) After the fill up, the
hydraulic oil must be between the upper and low marking of the oil level gauge or approx. 2
cm under the filler neck.
• Push button „lifting“ until the vent screws (on the top of the slave cylinders, see pic. 5) can be
reached. Execute a deaerate according to chapter 9.6, if necessary.
• Adjust the lift: first one base plate, than the second base plate. If there is an uneven floor
even it with metal sheets. A continuous contact between the floor and the base plate must be
guaranteed to avoid hollow spaces. Dowel the lift:
Nußbaum Company recommend safety dowels (e.g. LIEBIG German dowel manufacturer)
or equivalent dowels of other manufacturer but observe their regulations.
Before doweling check the concrete floor (with quality C20/25) if the concrete floor goes to
Содержание UNI-LIFT 3200 NT Plus ND
Страница 11: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 11 3 3 Data sheet...
Страница 16: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 16...
Страница 17: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 17...
Страница 18: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 18...
Страница 19: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 19...
Страница 20: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 20...
Страница 21: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 21...
Страница 23: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 23...
Страница 24: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 24...
Страница 25: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 25...
Страница 26: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 26...
Страница 27: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 27...
Страница 28: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 28...
Страница 29: ...Operating Instruction and Documentation UNI LIFT 3500 NT ND UNI LIFT 3200 NT Plus ND 29...