Operating instructions and documentation
4.65H/ 4.65 plus
- 31 -
During poor conditions it may be necessary to clean the lift once week, but cleaning once a month
will suffice.
Clean the lift and the floor with a non-aggressive and non-abrasive detergent. Use a gentle
detergent to clean the parts. Use a standard washing-up liquid and lukewarm water.
- Do not use steam jet cleaners.
- Remove all dirt carefully with a sponge or if necessary with a brush.
- Ensure that no washing-up liquid is left on the lift after cleaning.
- Do not use aggressive means for cleaning the workshop floor and the automotive lift.
- A permanent contact with any kind of liquid is not allowed. Do not use high pressure devices
for
cleaning the lift.
8 Security check
The security check is necessary to guarantee the safety of the lifting during use. It has to be
performed in the following cases:
1.
Before the initial operation, after the first installation
Use the form “First security check before initiation”
2.
In regular intervals after the initial operation, at least annually.
Use the form “Regular security check at least annually”
3.
Every time the construction of that particular lift has been changed.
Use the form “Extraordinary security check”
The first and the regular security check must be performed by a competent person. It
is recommended to maintain the lift at this occasion.
After changes to the construction of the lift and after serious maintenance works (i.e.
welding on carrying parts) an extraordinary security check must be performed by an
expert.
This manual contains form with a schedule for the security checks. Please us the adequate form for
the different security checks. The form should remain in this manual after they have been filled out.
In the following there is a short description about special safety devices.
9 Installation and Initiation
9.1 Regulations
•
The installation of the lift is performed by trained technicians of the manufacturer or one of its
distribution partners. If the operator can provide trained mechanics, he or she can install the lift
by him or herself. The installation has to be done according to this regulation.
• Installing the standard-automotive lift in a hazardous location or a washing bay is not allowed.
• Before installation a sufficient foundation must be constructed. If the foundation is already
constructed then proof that the foundation conforms to the standard is required.
A level foundation for the installation is required. The foundations must be based in a frost
resistance depth, both outdoors and indoors in a position where the installer believes there is no
chance of frost.
• An electrical supply 3~/N+PE, 400 V, 50 Hz must be provided.
The supply line must be protected with a time-lag fuse T16A (VDE0100 German regulation).
The minimum diameter amounts to 2.5 mm².
• All cable ducts must be equipped with protective coverings to prevent accidents.
Содержание 4.65H
Страница 9: ...Operating instructions and documentation 4 65H 4 65 plus 9 2 5 Declaration of conformity ...
Страница 11: ...Operating instructions and documentation 4 65H 4 65 plus 11 3 3 Datasheet ...
Страница 12: ...Operating instructions and documentation 4 65H 4 65 plus 12 ...
Страница 18: ...Operating instructions and documentation 4 65H 4 65 plus 18 3 8 Electrical diagram with wheel free jack ...
Страница 21: ...Operating instructions and documentation 4 65H 4 65 plus 21 Einspeisung supply Bild 2 N L3 L2 L1 PE ...
Страница 36: ...Operating instructions and documentation 4 65H 4 65 plus 36 9 7 Position of the columns ...