DISPLAY INDICATION
CAUSE
EFFECT
SOLUTION
CLEANING FILTER ALARM
Water Filter l.
20
The volume
counter has
reached the
number of litres
of deliverable
water set during
p r o g r a m m i n g
phase.
Coffee will not
be delivered;
the dose will not
be halted or it is
variable.
Regenerate cleaning filter salts.
To erase the alarm see paragraph
on ‘RESETTING CLEANING
FILTER LITRE COUNTER’.
This alarm blocks all deliveries.
The cleaning filter alarm can be
eliminated by programming the
number of litres to zero (see par-
agraph on ‘PROGRAMMING’).
TEMPERATURE PROBE
MALFUNCTION ALARM
Alarm: CoffeeTemp
Alarm: Steam Temp
One of the two
t e m p e r a t u r e
probes is broken.
Coffee will not
be delivered.
Replace the broken probe.
This alarm blocks all deliveries.
COFFEE QUANTITY ALARM
Too Much Coffee
Too much coffee. Coffee will not
be delivered
and an ejection
cycle will be
effected.
Reduce the quantity of coffee.