NTI UNIMUX MULTI-USER KVM SWITCH
56
Preparation For Upgrade
1. With the power to the UNIMUX OFF, connect the computer to the UNIMX as shown in the figure below.
Figure 52- Connect UNIMUX via RS232 for upgrading firmware
2. Power ON the computer only. Open the terminal console and apply the following settings to the terminal console for the port
connected to the UNIMUX:
Baud rate: 57600
Data bits: 8
Parity: none
Stop bits: 1
Flow control: none
Rear View of UNIMUX-4X8-UHD
VGA
Multi-Scan
Monitor
Control Terminal
RJ45-to-DB9 Adapter
(supplied)
CAT5 Patch Cable
(supplied)
RJ45-to-DB25 Adapter
(supplied)
or
RS232
CPU 1
CPU 2
CPU 5
CPU 6
CPU 7
CPU 8
CPU 3
CPU 4
USER 1
USER 2
USER 3
USER 4
AC INPUT
100-240VAC
10W
NTI
Tel:330-562-7070
Fax:330-562-1999
1275 Danner Dr
Aurora, OH 44202
www.networktechinc.com
R