List of CLI Commands: 

Command 

Purpose 

Command 

Purpose 

  help               

Show available commands 

  reset port            

reset port settings 

  quit                 

Disconnect 

  reset modem       

reset modem settings to 
factory default 

  logout              

Disconnect 

  reset user            

reset user settings to default 

  exit                  

Exit from current mode 

  update web_firmware  

update web firmware 

  history              

Show a list of previously run 
commands 

  update switch_firmware 

update switch firmware 

  config port baud 

config port baud 

  show port            

show port settings 

  config port lfsuppress 

config port linefeed suppress 

  show port baud    

show port baud 

  config port parity 

config port parity 

  show port parity    

show port parity 

  config port stop    

config port stop bits 

  show port stop       

show port stop bits 

  config port data    

config port data bits 

  show port data        

show port data bits 

  config port flow     

config port flow control 

  show port flow       

show port flow control 

  config port name   

config port name 

  show port name     

show port name 

  config port type      

config port type 

  show port type        

show port type 

  config port disconlen  

config port disconnect length 

  show port disconlen  

show port disconnect length 

  config port discon1   

config port disconnect 1 char 

  show port discon1     

show port disconnect 1 char 

  config port discon3  

config port disconnect 3 char 

  show port discon3     

show port disconnect 3 char 

  config port timeout  

config port timeout 

  show port timeout     

show port timeout 

  config port auth      

config port authentication 
method 

  show port auth        

show port authentication 
method 

  config port breakenable 

config port break enable 
status 

  show port breakenable  

show port break enable status 

  config port breaklen 

config port break length 

  show port breaklen    

show port break length 

  config port xon      

config port xon char 

  show port xon        

show port xon char 

  config port xoff      

config port xoff char 

  show port xoff        

show port xoff char 

  config port dtr       

config port dtr on connect 

  show port dtr         

show port dtr on connect 

  config port interchar 

config port interchar delay 

  show port interchar 

show port interchar delay 

  config modem init    

config port modem init string 

  show modem           

show modem 

  config modem hangup 

config port modem hangup 
string 

  show modem init      

show port modem init string 

  config modem reset    

config port modem reset 
string 

  show modem hangup  

show port modem hangup 
string 

  config modem nocarrier  

config port modem hangup on 
no carrier 

  show modem reset    

show port modem reset string 

  config user name     

config user name 

  show modem nocarrier  

show port modem hangup on 
no carrier 

  config user password  

config user password 

  show user            

user settings 

  config user level    

config user level 

  show user name   

show user name 

  config user enable  

config user enable 

  show user level     

show user level 

  config user timeout  

config user timeout 

  show user enable  

show user enable 

  config user initmenu  

config user init menu 

  show user timeout  

show user timeout 

  config user portaccess 

config user port access list 

  show user initmenu  

show user init menu 

  config admin timeout  

config admin timeout 

  show user portaccess 

show user port access list 

  config admin keypadpin 

config keypad pin 

  show admin timeout    

show admin timeout 

  config admin refresh  

config admin refresh time 

  show admin keypadpin 

show keypad pin 

  config admin password 

config admin password 

  show admin refresh   

show admin refresh time 

  config admin autouser 

config auto user to login 

  show admin autouser 

show auto user to login 

  config switch ipaddr 

config switch ip address 

  show switch ipaddr    

show switch ip address 

  config switch netmask  

config switch network mask 

  show switch netmask 

show switch network mask 

  config switch gateway 

config switch default gateway 
address 

  show switch gateway  

show switch default gateway 
address 

  config switch dns    

config primary dns 

  show switch dns       

show primary dns 

  config switch dns1   

config primary dns1 

  show switch dns1      

show primary dns1 

  config switch dhcp    

config dhcp for auto ip addr 

  show switch dhcp     

show dhcp for auto ip addr 

  config switch name    

config switch/host name 

  show switch name     

show switch/host name 

  config switch telnetbaseport   config telnet base port 

  show switch telnetbaseport  

show telnet base port 

  reboot               

reboot system 

  show firmware        

firmware revision 

  disconnect user  

disconnect user 

  show config          

config compared to default 
settings                 

  disconnect port   

disconnect port 

 

 

 
 

Содержание SERIMUX-CS-16

Страница 1: ...MAN088 Rev 5 27 10 SERIMUX CS x CONSOLE SWITCH Installation and Operation Manual SERIMUX Series...

Страница 2: ...twork Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users FIRMWARE VERSION Switch Firmware Version 1 14 Web Interface Ve...

Страница 3: ...vior 15 Inter character delay 15 Line break receive or transmit 15 Copy Port Serial Settings 16 Display serial settings for different port number 16 Modem settings 16 Port data buffer 17 Clear Port da...

Страница 4: ...Base Port 50 Firmware Update 51 Network Settings 52 Enterprise Settings 52 IP Configuration 52 Support 53 Reboot 53 Logout 53 Device Discovery Tool 54 Command Line Interface 55 Helpful Hints 57 Updat...

Страница 5: ...re 38 Connect Two Host Ports page 39 Figure 39 Clear Port Buffers page 40 Figure 40 Port Settings page 40 Figure 41 Change Port Settings page 41 Figure 42 Serial Settings page 41 Figure 43 Change Seri...

Страница 6: ...to host ports while serial user devices such as a terminal or serial console are connected to user ports The SERIMUX Console Switch supports two operator levels user and administrator Users login at u...

Страница 7: ...o it terminal program a terminal emulation program computer program that communicates via RS232 interface i e HyperTerminal dumb terminal Serial terminal device or CPU terminal program that emulates a...

Страница 8: ...Web Interface user name is root lower case letters only The default Web Interface password is nti lower case letters only For instruction on using the Web Interface see page 36 The default Keypad PIN...

Страница 9: ...nnector for connecting serial cable from a terminal console 9 Reset button For power cycling the SERIMUX firmware without powering down the SERIMUX 10 ISP button For use when restoring the firmware in...

Страница 10: ...threaded holes in the sides of the NTI switch Tighten the screws securely Figure 1 Secure rackmount ears to switch 2 Install 4 cage nuts supplied to the rack in locations that line up with the holes...

Страница 11: ...w the Initial Startup instructions on page 8 Figure 3 Connect terminals and devices to SERIMUX Console Switch Connect to the Ethernet If the Ethernet option is present the Web Interface page 36 will b...

Страница 12: ...source is used it should be connected to PWR 1 Note The power ON OFF switch is located on the front panel of SERIMUX when two IEC connectors are present Figure 5 Power connections for SERIMUX with Du...

Страница 13: ...flow control ANSI or VT100 terminal mode Within the SERIMUX firmware the CONSOLE port is identified as Port 0 For consistency when Port 0 is mentioned within this manual it refers to the terminal conn...

Страница 14: ...ge 32 for more info The default keypad PIN number is 9999 or 4444 for SERIMUX CS 4 Web Interface With an Ethernet connection to a LAN the user can remotely control SERIMUX port configuration and conne...

Страница 15: ...n changed from nti FYI If SERIMUX is not at initial power ON omit steps 2 and 3 above to login Figure 7 Administrator main menu FYI The Administrator main menu will also appear if a user with administ...

Страница 16: ...rt Pxx connected to that port If the administrator is logged in Adm will be displayed U H Port type User or Host Mdm Modem connection status Y if modem is connected if not BaudRate Port transmitter an...

Страница 17: ...on the administrator s timeout setting not based on the user s timeout setting If two ports are connected to each other and one port has a lower timeout setting than the other the lower setting will...

Страница 18: ...cal username and password required None no username or password is required Line Feed Suppress Telnet Enable or Disable Linefeed Suppression during Telnet session 0 Disable 1 Enable Default Reset Port...

Страница 19: ...on will be required for non standard baud rate values Data bit The data bit number can be 5 6 7 8 except for port 0 7 or 8 To modify the data bit number press 2 then the bit number 5 6 7 8 Stop Bit Th...

Страница 20: ...high active low inactive or pulsed for 0 5 seconds and then held high When a modem is attached to the port the DTR line will be pulsed on port disconnection disregarding this parameter value To modify...

Страница 21: ...attached to a SERIMUX port A minimum number of port modem settings can be adjusted in the SERIMUX to control the connection try the default values first refer to the manual s for the modems otherwise...

Страница 22: ...return to the Port settings menu Port data buffer From the Port settings menu press 7 to view the port data buffer In this display the administrator can see the last 508 characters received and transm...

Страница 23: ...User Name User name associated with the index number En User status Y enabled not enabled Adm Displays if user has administrative rights Y yes no Port access Displays what ports the user has access to...

Страница 24: ...ministrator privileges Enable administrative privileges for user Y to enable any other character to disable Port access Define ports user has access to Displays user s Port access list Fig 14 1 port n...

Страница 25: ...asterisk to start the paste function Three options are available The Y option is particularly useful if the administrator wants to place a particular user s settings into memory and move around to oth...

Страница 26: ...tings Define all network connection settings See Network Settings page 23 FYI If at power up the auto login user does not have access to port being used a login by a valid user with access rights will...

Страница 27: ...ave present firmware in SERIMUX to binary file Load new firmware To upgrade the firmware that controls the Console Switch as soon as improved versions become available download the firmware file from...

Страница 28: ...the extension bin i e SERIMUX1_8 bin With the file saved it can be restored from the CPU to the SERIMUX at any time if desired Network Settings From the Advanced settings menu press 9 to display the...

Страница 29: ...trator main menu press A to initiate a reboot of the SERIMUX You will be prompted to confirm the command before a reboot will occur After reboot you will need to reconnect to the SERIMUX to resume ope...

Страница 30: ...gram After login the user may connect to an allowed host port or view host status and parameters The user is unable to modify port parameters unless the user has been granted administrative privileges...

Страница 31: ...tion Keystroke Connect to host port 1 xx Enter where xx is the port index number Display Accessible host list 2 Enter Display accessible host and user ports and info about each 3 Enter Login as admini...

Страница 32: ...Usr Hst Port type user or host Modem Yes if modem is attached if not BaudRate Receiving and transmitting speed of the port Serial Character size parity and stop bit number Flow Defines flow control me...

Страница 33: ...mber of functions are possible Terse mode commands Connect to port Send or type in C xx Enter where xx is the port index number The answer will be OK CR LF LF FF If an error occurs i e the port is not...

Страница 34: ...n V Enter The answer will be OK CR LF and the Terse mode will be terminated The Accessible host list or the User main menu will be displayed User Logout Send or type in L Enter The answer will be OK C...

Страница 35: ...rmware menu pg 22 press 2 then Y to confirm All other ports will be disconnected and disabled during the firmware update procedure Note When using Port 0 for firmware file transfer if a different baud...

Страница 36: ...omatically restart after few seconds If not power down the SERIMUX power it back ON and press Enter Note Be sure that the baud rate setting of the terminal program is the same as that last configured...

Страница 37: ...5 seconds of each other for the SERIMUX to respond Otherwise the sequence will need to be repeated from the beginning Login the administrator Note In order to login the administrator to a port other t...

Страница 38: ...s pressed The administrator main menu Fig 7 page 10 will be displayed on the terminal application running on the administrator port The Administrator main menu will be displayed on the serial device c...

Страница 39: ...ise already connected and the port type is User the host port is not otherwise already connected and the port type is Host Disconnect and logout a user Action from Keypad Reaction of SERIMUX 1 Press D...

Страница 40: ...is pressed The modem will be initialized and connected if a modem is connected to the specified port and powered ON The administrator can verify this by viewing the Port list see page 8 To detach a m...

Страница 41: ...e address bar of the web browser Address To open a SSL encrypted connection type Address You will be prompted to accept a certificate Accept the NTI certificate A Welcome Page will appear Figure 31 We...

Страница 42: ...t is not currently in use the user has access to the port see page 46 With these conditions satisfied a Telnet connection will be initiated The user will be prompted to login with a SERIMUX user name...

Страница 43: ...fline see Figure 35 Then press Close at the bottom of the Telnet page see Figure 34 to exit Telnet Note If the user does not properly close a serial connection before exiting Telnet the user may not b...

Страница 44: ...Disconnect at the bottom of the page The associated port will be immediately disconnected and available for reconnection as needed Connect Two Host Ports Figure 38 Connect Two Host Ports page Under P...

Страница 45: ...at the bottom of the page The data buffer for the respective port will be cleared of all data Port Settings Figure 40 Port Settings page Under PORT CONFIGURATION select Port Settings to display the P...

Страница 46: ...cter 0 31 range see drop down list the default is Ctrl X Disconnect Character User defined characters to use when Disconnect sequence above is configured to be 3 characters Any 3 ASCII characters Conn...

Страница 47: ...communication characteristics associated with each port The characteristics that can be changed include Setting Value Baud Rate 50bps 128Kbps except port 0 between 300bps 115 2Kbps Data Bits 5 6 7 or...

Страница 48: ...open Figure 45 Change Modem Settings page The Change Modem Settings page provides boxes that can be edited with the modem communication characteristics associated with each port Refer to your modem i...

Страница 49: ...her ports as desired This enables the administrator to save time when configuring the SERIMUX As long as the connection status of the port to copy and the port s to be pasted to is No not connected th...

Страница 50: ...istrator can see who is enabled logged in and the timeout setting for each Disconnect User Figure 48 User Disconnect page Under User Management select Disconnect User the User Disconnect page Displays...

Страница 51: ...a list of each configured user and their connection status As long as the log in status for a user is No not logged the user settings for that user can be edited To proceed to the Change User Settings...

Страница 52: ...hat ports a user will have access to place a check mark in the Access box for each applicable port Copy User Settings Figure 51 Copy User Settings page Under USER MANAGEMENT select Copy User Settings...

Страница 53: ...sswords can be any 4 digit value from 0000 9999 The default value is 9999 4444 on SERIMUX CS 4 For security purposes the value entered will be displayed as asterisk Confirm Keypad PIN the password num...

Страница 54: ...alphabetical The password characters are displayed as asterisk characters while entering them NOTE If the administrator password is not known the administrator must re initialize the SERIMUX followin...

Страница 55: ...ccess the SERIMUX through Telnet If the base port number is 7000 the default value then ports 1 8 would be identified in Telnet as ports 7001 through 7008 respectively If the base port is changed to 7...

Страница 56: ...te is attempted using the wrong firmware for the section an error message will be received No update will occur 4 Wait for the following message to appear may take several minutes Upload Succeeded Fla...

Страница 57: ...ministrator can either define the network settings manually or let the DNS information be filled in automatically by the DHCP server If using the automatic method click the radio button for Obtain an...

Страница 58: ...59 When Reboot is selected the user will be prompted to confirm the selection When the reboot is complete the user will need to login again to resume operation of the SERIMUX Figure 60 Reboot the SER...

Страница 59: ...ery process After a few seconds the tool will display all NTI devices on the network along with their network settings Note Do not close this webpage while the NTI Discovery Tool is running Close the...

Страница 60: ...ction Enter the IP address assigned to the SERIMUX ANSI or VT100 terminal mode With the Telnet client properly configured you will immediately connect to the SERIMUX and be prompted for the administra...

Страница 61: ...nit config port modem init string show modem show modem config modem hangup config port modem hangup string show modem init show port modem init string config modem reset config port modem reset strin...

Страница 62: ...gure ports 1 through 4 all the same change 16 to 1 4 add 1 and a hyphen Helpful Hints Only one user can access the CLI at a time Most of the parameters can be set or viewed using the config or show co...

Страница 63: ...ERIMUX and written to flash memory This may take up to 5 10 minutes System will go to auto reboot within 10 seconds of each completed update Example IP address of Host on which the tftp server is runn...

Страница 64: ...cessor without actually power cycling the rest of the SERIMUX Figure 65 Location of RESET button Rear View of SERIMUX CONSOLE 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 25 26 27 28 29 30 31 32 21 22 23 24...

Страница 65: ...keypad are not accepted Buttons are being pressed too rapidly 1 Make sure the Keypad PIN is entered properly 2 Press the Enter key before typing the PIN to discard the previous entry 3 Try the PIN ag...

Страница 66: ...o break transmitted In band disconnect sequence 0 disabled 1 or 3 characters sequence 1 char sequence 1 character disconnect sequence Any ASCII nonprintable character 0 31 range Ctrl X 24 3 character...

Страница 67: ...5 Connector Pin Assignments RJ45 Signal DB 25M Signal 1 CTS Connected to 4 RTS 2 DSR 5 DCD Connected to 20 DTR 3 RxD Connected to 2 TxD 4 GND Connected to 7 GND 6 TxD Connected to 3 RxD 6 DCD 7 DTR Co...

Страница 68: ...2 TxD 4 GND Connected to 7 GND 6 TxD Connected to 3 RxD 6 DCD 7 DTR Connected to 8 DSR 8 RTS Connected to 5 CTS DB 25 Male Modem Adapter NTI P N DB25M RJ45F C DB 25 Male Modem to RJ45 Pin Assignment R...

Страница 69: ...ONS DESCRIPTION SPECIFICATION Connectors RJ45 Female DTE configuration via RS232 Operating temperature 32 F 100 F 0 C 38 C 17 90 non condensing RH Storage temperature 20 F 140 F 30 C 60 C 17 90 non co...

Страница 70: ...9 36 Password change 21 23 port access 20 port configuration 38 Port List 11 port settings 13 41 Quick start 8 rack mounting 5 reboot 24 53 serial communications 9 Serial Control 9 serial port charac...