NTI SERIMUX SERIES CONSOLE SWITCH
42
Under “PORT CONFIGURATION”, select “Serial Settings”. This page displays the number, name, and connection status of
each port. As long as the connection status for a port is “No” (not connected), the serial settings can be changed. To proceed
to the “Change Serial Settings” page for any non-connected port, select the desired Port Name. The Change Serial Settings
page for the respective port will open.
Figure 43- Change Serial Settings page
The Change Serial Settings page provides boxes that can be edited with the serial communication characteristics associated with
each port. The characteristics that can be changed include:
Setting
Value
Baud Rate
50bps-128Kbps (except port 0, between 300bps-115.2Kbps)
Data Bits
5, 6, 7, or 8 (except port 0, 7 or 8)
Stop bits
1, 2, or 1.5 (except port 0, 1 or 2 stop bits)
Parity
N (none), E (even), O (odd)
Flow Control
Hardware, Software, Both, or None
Xon Character
ASCII codes between 0 and 31 (see Fig. 9, pg. 13)
Xoff Character
ASCII codes between 0 and 31 (see Fig. 9, pg. 13)
DTR Line Behavior
High, Low, or Pulsed
Inter Character Delay
1-60 ms
Break Receive Allowed
Yes or No
Break Transmission Duration
1-999 ms or 0 to disable it
Once the desired changes have been made, press the “
Apply
” button to save the values. The changes will take effect