NTI SERIMUX SERIES CONSOLE SWITCH
61
Appendix A - SERIMUX Port Characteristics
Every port is defined through the following parameters:
Description
Acceptable Value
Default Value
Number
0-8/16/24/32
Same (not changeable)
Name
Up to 15 characters
“Port00” to “Port32”
Type – port 0
User
User (not changeable)
Type – except port 0
User or Host
Host
Baud rate – port 0
300-115200
9600
Baud rate – except port 0
50-128000
9600
Data bits per character – port 0
7,8
8
Data bits per character – except port 0
5,6,7,8
8
Stop bits – port 0
1, 2
1
Stop bits – except port 0
1, 1-1/2, 2
1
Parity
No parity, even, odd
No parity
Handshake mode (flow control)
Xon / Xoff (or in-band, or software),
RTS/CTS (or out-band or hardware),
Both,
None
None
Xon character
any ASCII nonprintable character (0-31 range)
Ctrl+Q (17)
Xoff character
any ASCII nonprintable character (0-31 range)
Ctrl+S (19)
Inter-character delay – except port 0
(no delay allowed on port 0)
1-60 milliseconds, none
None
Line break receive allowance – except port 0
(no allowance for port 0)
Yes or No
No
Transmitted line break extra duration (added
to 1 character transmission time) – except
port 0 (no extra duration for port 0)
No break transmitted, 1-999 milliseconds
No break transmitted
In-band disconnect sequence
0 (disabled), 1, or 3 characters sequence
1-char sequence
1 character disconnect sequence
Any ASCII nonprintable character (0-31 range)
Ctrl+X (24)
3 character disconnect sequence
Any 3 ASCII characters
``` (3 back quotes)
Connection timeout
1-90 minutes, never
15 minutes
DTR output upon disconnect
Low, high, or pulsed for 0.5 seconds and then held
high
High
Modem Reset string
Up to 41 characters
ATZ
Modem Initialization string
Up to 41 characters
AT&F&C1&D2S0=0
Modem Disconnect string
Up to 41 characters
ATH
Appendix B - SERIMUX User and Administrator Characteristics
The users and the administrator are defined through the following parameters:
Description
Acceptable Value
Default Value
Users:
User number
1 to 32
Same (not changeable)
User name
Up to 15 characters – case sensitive
“User01” to “User32”
User password
Up to 31 characters – case sensitive
“” (empty string)
User enabled
Yes or No
Not enabled, except
User 1: enabled
Administrative privileges
Yes or No
No
Access to ports
Port 0 always; Ports 1-31
Port 0, except
User 1: all ports
User menu timeout
1-90 minutes, never
15 minutes
Administrator:
Administrator name
“ADMINISTRATOR” or “ROOT” – case sensitive
Same (not changeable)
Administrator password
Up to 31 characters – case sensitive
“NTI”
Administrator menu timeout
1-90 minutes, never
15 minutes
User to auto login
User 1-32, None
User 1