Part 1 - General Safety Information
Part 4 - Water Piping
NOTES:
1. This drawing is meant to show piping concept only. Installer is
responsible for all equipment and detailing required by local codes.
2. The minimum pipe size of DHW piping should be ¾” diameter.
3. Install a minimum of 12 diameters of straight pipe upstream of all
circulators.
4. Circuit setter must be set at 0.5 GPM.
5. Turn “Comfort” Function ON. Set Parameter 2.5.0 to 1 or 2.
6. For efficient operation, it is recommended to use a recirculation
pump with a pulse function, such as TACO 006E with Smart Plug.
7. Drains and ball valves will aid in purging recirculation line.
The piping will not support the weight of the circulators. Refer to
the circulator manufacturer’s instructions to properly support the
circulator. Failure to comply with these instructions could result in
property damage, severe personal injury, or death.
WARNING
Figure 21 - Combi Boiler with Recirculation