Technical Information
JP5 (SCA Remote/Delay start)
75
JP5 (SCA Remote/Delay start)
CAUTION:
Jumper configuration to be performed by qualified service personnel only.
The spin-up of the drive slots is determined by adding jumpers to JP5. JP5 is a two
position dual-row header. Position 1 & 2 control the “Delayed_Start” signal and
position 3 & 4 control the “Remote_Start” signal.
ON
ON
ON
OFF
10, 11, 12, 13
OFF
ON
ON
OFF
10, 11, X, X
Jumper Positions for Drives 5, 6, 7, and 8 ID Settings
9 & 10
11 & 12
13 & 14
15 & 16
SCSI ID (5, 6, 7, and 8)
ON
ON
ON
ON
0, 1, 2, 3
OFF
ON
ON
ON
0, 1, 2, 4
ON
OFF
ON
ON
4, 5, 6, 7
OFF
OFF
ON
ON
4, 5, 6, 8
ON
ON
OFF
ON
5, 6, 7, 8
OFF
ON
OFF
ON
5, 6, 8, 9
ON
OFF
OFF
ON
8, 9, 10, 11
OFF
OFF
OFF
ON
9, 10, 11, 12
ON
ON
ON
OFF
10, 11, 12, 13
OFF
ON
ON
OFF
10, 11, X, X
Pins 1 and 2
Pins 3 and 4
Drive Spinup Mode
ON
ON
Motor spins up only on SCSI
“start” commands.
ON
OFF
Motor spins up after a delay of 12
(may vary depending on drive
type) seconds times the numeric
SCSI ID setting of the associated
drive.
Jumper Positions for Drives 1, 2, 3, and 4 ID Settings
1 & 2
3 & 4
5 & 6
7 & 8
SCSI ID (1, 2, 3, and 4)
JP5
REMOTE
DELAY
1
2
4 3
Содержание CR8e