background image

Fig. 4

8

9

(1) Charge (if batteries are used)

1) Insert the AC Adaptor plug into a power supply.
2) The AC IN lamp lights in green.
3) The internal microcomputer checks the voltage of the batteries and starts charging, if necessary. If it starts charging, the 

CHARGE lamp lights, and the mark of the remaining amount of the batteries on the LCD panel will be animated.
* There is no need to turn on the power.

4) When the CHARGE lamp turns off, charging has been completed.

5. HOW TO USE

(1) Connecting Motor Handpiece

Align the      mark of the Motor Handpiece Cord Plug of the 
motor handpiece with the     mark of the motor handpiece 
connector and insert the plug until it locks. (Fig. 3)

(2) Connecting AC Adaptor

Insert the jack of the AC Adaptor into the power connector 
with the       mark of the jack cast down. (Fig. 4)

(3) Connecting Foot Control (Option)

Securely insert the plug of the Foot Control (Option) into the 
Foot Control Connector with the      mark of the plug cast 
down. (Fig. 5)

* You do not have to connect the Foot Control, if you intend 

to use this product without the Foot Control.

4. HOW TO CONNECT EACH PART

• Do not connect other than AC120V or AC 230V. If it connects to others, it may cause a malfunction.
• Since the AC IN lamp lights to indicate that the supply power is on, it does not go out even after a charge is 

completed. See the CHARGE lamp to check the charging conditions.

• The charging normally takes approx. 5 hours, but it depends on battery use conditions. Older batteries are 

especially prone to significantly shorter charging and operating times.

• The temperature of the batteries is measured during charging. Proper charging cannot be preformed if the 

charger is placed in an environment which is subject to sharp temperature change (next to window, subject to 
direct sunlight, near air outlet or fan heater). Place it in a place where temperature change is minimal.

• Charging may not be started in the following case:

 The temperature of a battery is too low or too high. (less than 0°C (32°F) or more than 40°C (104°F). ) 

 The temperature of the batteries is executively high or low. (Lower than apporox. 0 degree or higher than 

approx. 40 degree)

 A battery is not connected.

 The voltage of a battery is abnormal. (See P.16  10. “ERROR CODE”)

• Batteries are automatically charged depending on conditions, even when the power is on. But when the motor 

handpiece is used, charging is suspended to protect the battery.

CAUTION

To remove the plug, hold the plug ring and pull it out.

NOTICE

• Bar Display

LCD

It displays the bar graph which shows the degree of load applied to the motor while 
the file is in motion.

Fig. 3

Fig. 5

Foot Control (option) Plug

Foot Control (option) Plug

Foot Control Connector

Foot Control Connector

Fig. 6

AC IN Lamp

AC IN Lamp

REVERSE Key

REVERSE Key

CHARGE Lamp

CHARGE Lamp

AUTO REVERSE Key

AUTO REVERSE Key

POWER Key

POWER Key

MEMORIZE Key

MEMORIZE Key

GEAR RATIO Key

GEAR RATIO Key

SPEED Key

SPEED Key

TORQUE Key

TORQUE Key

PROGRAM Key

PROGRAM Key

Motor Handpiece

Cord Plug

Motor Handpiece

Cord Plug

Motor Handpiece Connector

Motor Handpiece Connector

Ring

Jack of the AC Adaptor

Jack of the AC Adaptor

Power Connector

Power Connector

Содержание ENDO-MATE DT

Страница 1: ...OPERATION MANUAL Please read this Operation Manual carefully before use and file for future reference OM E0202E 002 Motor Handpiece System for Root Canal Enlargement...

Страница 2: ...this Operation Manual for future reference Read these safety cautions thoroughly before use and operate the product properly These indicators are to allow you to use the product safely and prevent da...

Страница 3: ...ged deformed or non ISO conforming file Using such a file may result in personal injury due to its unexpected breaking or flying off during rotation Do not use or leave the product in a high temperatu...

Страница 4: ...though it is not used It is recommended to recharge the batteries just before use When the motor handpiece stops automatically by detecting a low battery voltage turning on the power again after a whi...

Страница 5: ...luding motor handpiece cord Fig 1 2 3 8 10 9 1 12 4 5 6 7 11 Option Control Unit Operation Panel See Fig 2 Operation Panel and LCD Panel LCD Panel See Fig 2 Operation Panel and LCD Panel Error codes a...

Страница 6: ...pending on the rotation speed Operation Panel and LCD Panel Fig 2 LCD Panel This indicates that all displays are lighted TORQUE Key The torque limit values can be changed If the speed is to exceed the...

Страница 7: ...available at 1 1 4 1 10 1 16 1 and 20 1 REVERSE Key The rotational direction of the file can be changed by this key It can also be changed while the file is in motion The alarm sounds during reverse...

Страница 8: ...on of the power LCD The mark of the present remaining amount of the batteries is displayed regardless of the ON or OFF position of the power The mark will be animated when the batteries are being char...

Страница 9: ...he mark of the plug cast down Fig 5 You do not have to connect the Foot Control if you intend to use this product without the Foot Control 4 HOW TO CONNECT EACH PART To remove the plug hold the plug r...

Страница 10: ...imes The temperature of the batteries is measured during charging Proper charging cannot be preformed if the charger is placed in an environment which is subject to sharp temperature change next to wi...

Страница 11: ...t gear ratio is selected according to the contra angle head in use an adequate rotation speed and torque limit value can be set 4 Select the rotational direction by pressing the REVERSE key The key ch...

Страница 12: ...tion 5 Operation 1 Start the motor handpiece to pressing the ON OFF button briefly Press the button again may stop the handpiece Alternate operation Keep pressing ON OFF button more than a second the...

Страница 13: ...or more than one second If the program number is changed by the PROGRAM key without pressing the MEMORIZE key the initially memorized preset values remain Cancel function NOTICE 6 Completion of Medica...

Страница 14: ...play at the time of charging At the same time the CHARGE lamp flashes slowly 5 Leave it as it is The batteries are discharged and recharged automatically 6 Hold down the POWER key for a while when you...

Страница 15: ...ad for 2 3 seconds Fig 12 2 Cleaning Motor Handpiece When the motor handpiece becomes dirty wipe it off with a cotton cloth moistened with rubbing alcohol 7 CLEANING Do not lubricate the motor section...

Страница 16: ...out the old batteries and pull out the cord holding it at the connector Fig 14 4 Insert the connector of the cord of new batteries into the connector in accordance with the polarity indication label...

Страница 17: ...on of the circuit may be suspected Contact your dealer Malfunction of circuit The motor handpiece is locked at the time of the auto reverse mode Malfunction of circuit High load was continuously appli...

Страница 18: ...batteries is high An error code is displayed Check the connection Check the connection Charge the batteries or use the AC Adaptor Insert batteries or use the AC Adaptor Contact your dealer Check the c...

Страница 19: ...t is rotated by the Foot Control Option Clean or replace the contra angle head Contact your dealer Check the ON OFF button Contact your dealer Check the Foot Control Option Remove the foot control Opt...

Страница 20: ...tronic equipment The ENDO MATE DT is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supply ne...

Страница 21: ...electromagnetic immunity The ENDO MATE DT is intended for use in the electromagnetic environment specified below The customer or the user of the ENDO MATE DT should assure that it is used in such an e...

Страница 22: ...vent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the ENDO MATE DT as recommended below according to the maxi...

Страница 23: ...Specifications are subject to change without notice 2014 11 20 02 M The EU directive 93 42 EEC was applied in the design and production of this medical device...