Manufacturer warrants its products to the original purchaser against defects in material and workmanship under normal 
practices of installation, use and servicing. Batteries etc. are expendable components, and are not covered by this 
warranty.

13. WARRANTY

• Please consult with dealer from whom you purchased it about waster despoil.
• The used nickel metal hydride batteries are recyclable, but their disposal may sometimes not be permitted by the 

country. Return them to your dealer.

14. DISPOSING PRODUCT

Symbols

* The incons beside of the models are showing reduction gear ratio of the head.          20:1 Reduction,      4:1 Reduction
* Files are not included.

12. CONTRA ANGLE HEAD

 (OPTION)

Problem

Cause

Solution

Head

Model

Product No.

Specifications

Guidance and manufacturer's declaration - electromagnetic emissions

The ENDO-MATE DT is intended for use in the electromagnetic environment specified below. The customer or the user of the ENDO-MATE DT should assure that is 
used in such an environment.

Emissions test

Compliance

Electromagnetic environment - guidance

RF emissions
CISPR11

RF emissions
CISPR11

Harmonic emissions
IEC61000-3-2

Voltage fluctuations/flicker emissions
IEC61000-3-3

Group 1

Class B

Class A

Complies

The ENDO-MATE DT uses RF energy only for its internal function. Therefore, its RF emissions are 
very low and are not likely to cause any interference in nearby electronic equipment.

The ENDO-MATE DT is suitable for use in all establishments, including domestic establishments and 
those directly connected to the public low-voltage power supply network that supply network that 
supplies buildings used for domestic purposes.

The motor handpiece does 
not rotate. (“             ” and 
the rotation speed are 
displayed alternately.)

When turning on the power, 
the alarm sounds, and the 
motor handpiece does not 
rotate.

The motor handpiece keeps 
rotating. (The Foot Control 
(Option) does not react.)

The motor handpiece keeps 
rotating. (The ON/OFF 
button does not react.)

The contra angle head is clogged.

There is a short circuit inside the motor 
handpiece or the motor handpiece cord.

The power is turned on while pressing the 
ON/OFF button.

There is a short circuit inside the ON/OFF 
button.

The power is turned on while pressing the 
Foot Control (Option).

There is a short circuit inside the Foot 
Control. (Option)

It is rotated by the ON/OFF button.  

It is rotated by the Foot Control (Option).

Clean or replace the contra angle head.

Contact your dealer.

Check the ON/OFF button.

Contact your dealer.

Check the Foot Control (Option).

Remove the foot control (Option), and rotate 
the motor handpiece by the ON/OFF button, 
or contact your dealer.

Stop the rotation by the ON/OFF button.

Release your foot from the Foot Control 
(Option) to stop, or pull out the plug of the 
Foot Control (Option).

Y110044

Y110047

Y110045

Y110051

Y110046

Y110052

Y110053

Y110018

Y110054

Y110033

Y110055

Y110056

MP-F20R

MP-F4R

MPA-F20R

MPA-F4R

MPAS-F20R

MPAS-F4R

NML-F20R

NML-F4R

NMA-F20R

NMA-F4R

NMAS-F20R

NMAS-F4R

• Mini Head  • 360°rotation

• 20:1 / 4:1 Reduction

• For Ni-Ti files (ø2.35)

• Mini Head  • 360°rotation

• 20:1 / 4:1 Reduction

• For Ni-Ti files (ø2.35)

• To connect with Apex Locator
• Mini Head  • 360°rotation

• 20:1 / 4:1 Reduction

• For Ni-Ti files (ø2.35)

• To connect with Apex Locator

• Mini Head  • 360°rotation

• 20:1 / 4:1 Reduction

• For Ni-Ti files (ø2.35)

• Mini Head  • 360°rotation

• 20:1 / 4:1 Reduction

• For Ni-Ti files (ø2.35)

• To connect with Apex Locator
• Mini Head  • 360°rotation

• 20:1 / 4:1 Reduction

• For Ni-Ti files (ø2.35)

• To connect with Apex Locator

TUV Rhineland of North America is a Nationally Recognized Testing Laboratory (NRTL) in the United States and is accredited by 
the Standards Council of Canada to certify electro-medical products with Canadian National Standards.

Follow the waste of electric and electronic equipment (WEEE) Directive (2012/19/EU) to dispose of the product and accessories.

Consult operation instructions.

This conforms to CE European Directive of “Medical equipment directive 93/42/EEC.”

Protected against vertically falling water drops.

Manufacturer.

Type B conforming component

Authorised representative in the European community.

Marking on the outside of Equipment or Equipment parts that include RF transmitters or that apply RF electromagnetic energy 
for diagnosis or treatment.

Autoclavable up to Max.135°C.   *for detail see Sterilization.

Class II equipment.

Short-circuit-proof safety isolating transformer.

For indoor use only.

To identify fuse boxes or their location.

This product meets UL safety standard requirements.

This mark is machine tool, electrical equipment and medical equipment Safety mark in Canada.

Содержание ENDO-MATE DT

Страница 1: ...OPERATION MANUAL Please read this Operation Manual carefully before use and file for future reference OM E0202E 002 Motor Handpiece System for Root Canal Enlargement...

Страница 2: ...this Operation Manual for future reference Read these safety cautions thoroughly before use and operate the product properly These indicators are to allow you to use the product safely and prevent da...

Страница 3: ...ged deformed or non ISO conforming file Using such a file may result in personal injury due to its unexpected breaking or flying off during rotation Do not use or leave the product in a high temperatu...

Страница 4: ...though it is not used It is recommended to recharge the batteries just before use When the motor handpiece stops automatically by detecting a low battery voltage turning on the power again after a whi...

Страница 5: ...luding motor handpiece cord Fig 1 2 3 8 10 9 1 12 4 5 6 7 11 Option Control Unit Operation Panel See Fig 2 Operation Panel and LCD Panel LCD Panel See Fig 2 Operation Panel and LCD Panel Error codes a...

Страница 6: ...pending on the rotation speed Operation Panel and LCD Panel Fig 2 LCD Panel This indicates that all displays are lighted TORQUE Key The torque limit values can be changed If the speed is to exceed the...

Страница 7: ...available at 1 1 4 1 10 1 16 1 and 20 1 REVERSE Key The rotational direction of the file can be changed by this key It can also be changed while the file is in motion The alarm sounds during reverse...

Страница 8: ...on of the power LCD The mark of the present remaining amount of the batteries is displayed regardless of the ON or OFF position of the power The mark will be animated when the batteries are being char...

Страница 9: ...he mark of the plug cast down Fig 5 You do not have to connect the Foot Control if you intend to use this product without the Foot Control 4 HOW TO CONNECT EACH PART To remove the plug hold the plug r...

Страница 10: ...imes The temperature of the batteries is measured during charging Proper charging cannot be preformed if the charger is placed in an environment which is subject to sharp temperature change next to wi...

Страница 11: ...t gear ratio is selected according to the contra angle head in use an adequate rotation speed and torque limit value can be set 4 Select the rotational direction by pressing the REVERSE key The key ch...

Страница 12: ...tion 5 Operation 1 Start the motor handpiece to pressing the ON OFF button briefly Press the button again may stop the handpiece Alternate operation Keep pressing ON OFF button more than a second the...

Страница 13: ...or more than one second If the program number is changed by the PROGRAM key without pressing the MEMORIZE key the initially memorized preset values remain Cancel function NOTICE 6 Completion of Medica...

Страница 14: ...play at the time of charging At the same time the CHARGE lamp flashes slowly 5 Leave it as it is The batteries are discharged and recharged automatically 6 Hold down the POWER key for a while when you...

Страница 15: ...ad for 2 3 seconds Fig 12 2 Cleaning Motor Handpiece When the motor handpiece becomes dirty wipe it off with a cotton cloth moistened with rubbing alcohol 7 CLEANING Do not lubricate the motor section...

Страница 16: ...out the old batteries and pull out the cord holding it at the connector Fig 14 4 Insert the connector of the cord of new batteries into the connector in accordance with the polarity indication label...

Страница 17: ...on of the circuit may be suspected Contact your dealer Malfunction of circuit The motor handpiece is locked at the time of the auto reverse mode Malfunction of circuit High load was continuously appli...

Страница 18: ...batteries is high An error code is displayed Check the connection Check the connection Charge the batteries or use the AC Adaptor Insert batteries or use the AC Adaptor Contact your dealer Check the c...

Страница 19: ...t is rotated by the Foot Control Option Clean or replace the contra angle head Contact your dealer Check the ON OFF button Contact your dealer Check the Foot Control Option Remove the foot control Opt...

Страница 20: ...tronic equipment The ENDO MATE DT is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supply ne...

Страница 21: ...electromagnetic immunity The ENDO MATE DT is intended for use in the electromagnetic environment specified below The customer or the user of the ENDO MATE DT should assure that it is used in such an e...

Страница 22: ...vent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the ENDO MATE DT as recommended below according to the maxi...

Страница 23: ...Specifications are subject to change without notice 2014 11 20 02 M The EU directive 93 42 EEC was applied in the design and production of this medical device...