I/F 501
INTERFACE UNIT
INSTALLATION AND OPERATION GUIDE
Software Revision 1.05, Version A
INTRODUCTION
The I/F 501 interface unit allows a variety of comunication protocals used in NSI and other industrial equipment
to be translated between one another. In addition the I/F 501 can serve as an independent, programmable lighting
controller. The I/F 501 also serves as the interface between NSI’s Luma-net network and a personal computer.
SPECIFICATIONS:
Microplex Input (I/O)
3 pin XLR male
Microplex Ouput (I/O)
3 pin XLR female
DMX 512 Input
5 pin XLR male (USITT spec)
DMX 512 Output
5 pin XLR female (USITT spec)
AMX 192 Output (optional, replaces 512)
4 pin XLR female (USITT spec)
RS-232 I/O
9 pin ‘‘D’’ connector
MIDI input / Analog input
5 pin din 180 degree connector
Luma-net I/O
Modular style telephone connector
Power requirements
+15VDC 200ma (power supply included)
IMPORTANT
Although many different connectors are present on this unit, in most configurations, one or more of the connectors
may serve no function. It is important that the installer verify that the required inputs and outputs operated in the
mode required for the application. Please read the appropriate application sheets in this manual carefully before
installing.