ANALOG TO AMX-192
In this application, 0 - 10VDC is converted to AMX 192.
CONNECTOR
OPERATION
Microplex IN
Input Microplex
Microplex OUT
Not Used
DMX IN
Input DMX 512
**DMX out
Output AMX 192
MIDI / Analog
0-10VDC input
Luma-net
Not Used
RS-232
Not Used
JUMPER LOCATIONS
P4 & 5
P7
JP6 & 7
JP8 & 9
JP10
JP11
JP12
JP13
OPEN
OPEN
N/A
2-3
2-3
2-3
N/A
2-3
P6
P8
JP1
DMX OUT CABLE
*CLOSE TO TERM
DMX
N/A
N/A
JP3
DIPSWITCH POSITIONS
C1
C2
C3
C4
ADDRESS 1 - 7
A8
UP
UP
DN
UP
STARTING ADDR OF ANALOG CHAN 1 BY 1 INCREMENT
Four analog 0-10V channels are merged with DMX-512 or Microplex and output as AMX-192.
Channel number of first analog channel is determined by A1-7.
AMX output is sent as either 64 or 128 channels, depending on the setting of switch A8.
*Close P6 if inputting DMX. IF 501 is always last device at end of DMX line.
**IMPORTANT - Move AMX output connector jumper from JP4 to JP3.
INTERFACE UNIT
Software Revision 1.05, Version A
ANALOG TO AMX-192
NSI CORPORATION
17