Connect Cable to Controller
Route the sensor cable into the nacelle and to its connection point. It may be helpful to label the end of
each wire before pulling the cable to its connection point. Following the color code, connect the sensor
wires and shield wire to the turbine controller and heater power supply.
Sensor Common
Black, 22 AWG
Sensor Power
Red, 22 AWG
Sensor Signal
White, 22 AWG
N/A – not used
Yellow, 22 AWG (on all cables shipped since January, 2016)
Heater – *
Orange/White, 20 AWG
*
Orange/Black, 20 AWG
When powering the sensor heater with DC power, Orange/White MUST be connected
to DC Ground (-) and Orange/Black to 24V DC (+).
When using AC power, the wiring order does not matter.