NRG Product Manual
Hybrid XT Anemometer
HybridXT_Anemometer_Manual
Rev. 15
[email protected] | Page 12
02 January 2020
HXT Sensor-to-Cable Compatibility
Sensor Part
Number
Sensor Type |
Output Type
Compatible Cable
Part Numbers
Notes
4715
HXT Vane |
Digital Frequency
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected
4718
HXT Anemometer |
Digital Frequency
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected
6624
HXT Anemometer,
Calibrated |
Digital Frequency
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected
5762
HXT Vane |
4-20 mA, Clockwise
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected
5763
HXT Anemometer |
4-20 mA, 0-50 m/s
scaled
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected
7894
HXT Vane |
Push-Pull, Active
Low
8797, 9234, 9319
(Red,
Orange
or
Chartreuse
tag) only
Only newer 6-pin cables can be used
All six wires are required to provide
both Vane signals.
7901
HXT Anemometer |
Push-Pull
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected
9362
HXT Vane |
4-20 mA, Counter-
Clockwise
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected
9363
HXT Vane | Push-
Pull, Active High
8797, 9234, 9319
(Red,
Orange
or
Chartreuse
tag) only
Only newer 6-pin cables can be used
All six wires are required to provide
both Vane signals.
9365
HXT Anemometer |
4-20 mA, 0-60 m/s
scaled
4716, 4717, 8797,
9234, 9319
Any cable may be used
Yellow (Output 2) is not used and
should be left disconnected