Be sure that the connector is snug against the top of the mounting mast and that the washer is on the
bolt (compression of the rubber washer may be necessary) then pass the bolt though the mast and
connector. Now attach the nut to the bolt a few turns until the nylon patch is in contact with the nut.
The nylon patch prevents the nut from backing off the bolt threads. Note that the washer is between
the mounting mast and the bolt head.
The HXT sensors have four ridges running vertically
inside the body's lower end as shown in the picture
below. These ensure that the sensor mounts securely
on the mounting mast.
If attaching the shield to the ground screw,
make sure that it does not interfere with the
mounting ridges by running it straight down the
mast from the connector to the ground screw.
Do not wrap the wire around the mast. The
picture below shows the ground screw
attachment option.
Secure connector to mast with bolt,
washer, and nut.
SS washer away
from mast to
allow sensor to
slide in place
Connector and
rubber washer
snug to mast
Suggested method for attaching shield to mast.