5-4. AC characteristics
5-4-1. Reference clock
1) When setting CKSL = L
Item
Symbol
Min.
Max.
Unit
Frequency
f
CLK
-
40
MHz
Cycle
T
CLK
25
-
ns
HIGH duration
T
CLKH
10
15
ns
LOW duration
T
CLKL
10
15
ns
Note: In order to secure good communication quality, use a clock offering the nearest figures to the standards
above.
For details, see the "CLK" section of the "Terminal Function" in this manual.
2) When setting CKSL = H
Item
Symbol
Min.
Max.
Unit
Frequency
f
CLK
-
80
MHz
Cycle
T
CLK
12.5
-
ns
HIGH duration
T
CLKH
-
-
ns
LOW duration
T
CLKL
-
-
ns
5-4-2. Reset timing
Item
Symbol
Min.
Max.
Unit
Reset length
T
WRSTI
10
-
Clock cycles
Delay time
T
DRST
-
10
Clock cycles
Note 1: After the internal RST goes LOW, the I/O device (G9002A) will be ready.
Note 2: The reset signal must last at least 10 cycles of the reference clock.
While resetting, make sure the clock signal continuously available to the device.
If the clock is stopped while resetting, the device cannot be reset normally.
____
RST
T
DRST
T
WRSTI
Internal
RST
T
DRST
Содержание Motionnet G9001A
Страница 1: ...DA70131 1 3E G9001A G9002A User s Manual Center device I O device Remote I O Remote Motion...
Страница 7: ...DA70131 1 3E I 1 I Center device G9001A User s Manual...
Страница 8: ...DA70131 1 3E I 2...
Страница 50: ...DA70131 1 3E I 44...
Страница 51: ...DA70131 1 3E II 1 II I O device G9002A User s Manual...
Страница 52: ...DA70131 1 3E II 2...
Страница 66: ...DA70131 1 3E II 16...
Страница 67: ...DA70131 1 3E III 1 III Connection Examples and Recommended Environments G9000 Series...
Страница 68: ...DA70131 1 3E III 2...
Страница 87: ...DA70131 1 3E IV 1 IV Software Examples flow chart G9001A...
Страница 88: ...DA70131 1 3E IV 2...