DA70131-1/3E
I-27
4-8-2. Memory access command
Command
Description
0101 0000 0### ##xx
(5000h to 507Fh)
Writes data to the "device information" area.
The data in the input/output buffer are written into one word of the device information
area.
Relationship between the contents of the input/output buffer and the area is shown in
the table below.
Command
Input/output
buffer
Address
Device No.
5000h
bit 7 to 0
078h
0
bit15 to 8
079h
1
5004h
bit 7 to 0
07Ah
2
bit15 to 8
07Bh
3
5008h
bit 7 to 0
07Ch
4
bit15 to 8
07Dh
5
500Ch
bit 7 to 0
07Eh
6
bit15 to 8
07Fh
7
0101 0001 0##x xxxx
(5100h to 517Fh)
Writes to the "cyclic communication error flag" area.
The contents of the input/output buffer are written into one word of the above area.
0101 0010 0### #xxx
(5200h to 527Fh)
Writes to the "input change interrupt setting" area.
The contents of the input/output buffer are written into one word of the above area.
0101 0011 0### #xxx
(5300h to 537Fh)
Writes to the "input change interrupt flag" area.
The contents of the input/output buffer are written into one word of the above area.
0101 0100 0### ###&
(5400h to 547Fh)
Writes to the "port data" area.
The contents of the input/output buffer are written into one word of the above area.
0110 0000 0### ##xx
(6000h to 607Fh)
Reads the "device information" area.
The contents of one word in the above area are copied to the input/output buffer.
0110 0001 0##x xxxx
(6100h to 617Fh)
Reads the "cyclic communication error flag" area.
The contents of one word in the above area are copied to the input/output buffer.
0110 0010 0### #xxx
(6200h to 627Fh)
Reads the "input change interrupt setting" area.
The contents of one word in the above area are copied to the input/output buffer.
0110 0 11 0### #xxx
(6300h to 637Fh)
Reads the "input change interrupt flag" area.
The contents of one word in the above area are copied to the input/output buffer.
0110 0100 0### ###&
(6400h to 647Fh)
Reads the "port data" area.
The contents of one word in the above area are copied to the input/output buffer.
Note: Bit with # symbol; Set upper bit of the device address from the upper side of the # bit.
Bit with & symbol; Assign "0" for port 0 and 1 and assign "1" for port 2 and 3.
Bit with x symbol; Any value is available.
If all of the address map (512 bytes), required by the center device, are allocated so as the CPU can review
the whole of them, the commands described on this page are not needed.
If resources administrated by the CPU are shorted and only 8 bytes can be secured for the center device,
by using the commands described on this page, the CPU can access all of the addresses the center device
has.
Содержание Motionnet G9001A
Страница 1: ...DA70131 1 3E G9001A G9002A User s Manual Center device I O device Remote I O Remote Motion...
Страница 7: ...DA70131 1 3E I 1 I Center device G9001A User s Manual...
Страница 8: ...DA70131 1 3E I 2...
Страница 50: ...DA70131 1 3E I 44...
Страница 51: ...DA70131 1 3E II 1 II I O device G9002A User s Manual...
Страница 52: ...DA70131 1 3E II 2...
Страница 66: ...DA70131 1 3E II 16...
Страница 67: ...DA70131 1 3E III 1 III Connection Examples and Recommended Environments G9000 Series...
Страница 68: ...DA70131 1 3E III 2...
Страница 87: ...DA70131 1 3E IV 1 IV Software Examples flow chart G9001A...
Страница 88: ...DA70131 1 3E IV 2...