Handset with memory function
EN
EN
-
Window stop setting
This function is used to limit the height adjustment function; once the table has been set, it cannot normally be
moved above the set stop point.
•
Move the frame to the position you want for the stop point.
•
Touch and hold the "
S
" key, immediately press the "
3
" key and hold both for approx. 4 seconds
pressed.
-
> The letter "
_L_
" is now displayed. This means that the table is locked in the lowest position is to
which it can be moved.
•
Let go of the buttons
-
> The setting is saved and the process is now complete
Note on the stop positions
Any memory positions occupied below or above are lost as soon as a stop point has been set.
Delete the stop points
•
Touch and hold the "
S
" key, immediately press the "
2
" key and hold both for about 6 seconds
pressed.
-
> The letter "
_L_
" is now displayed. This means that the table is locked in the lowest position is to
which it can be moved.
•
Release the keys
-
> The setting is saved and the process is now complete
•
Hold down the "
S
" key, then hold down the "
2
" key for approx. 6 seconds until "
C
" on the display
appears.
-
> Letter
“
C
”
is shown on the display. This means that the stop points are removed and the full stroke of
the table can be used again.
•
Release the keys
-
> The setting is saved and the process is now complete
Setting the sensitivity of the orientation sensor
The orientation sensor serves as an improved collision sensor. If a table encounters a fixed obstacle during the
height adjustment, this can be detected by the sensor and immediately triggers an interruption in the height
adjustment. In addition, the frame moves a bit in the opposite direction to release the obstacle.
Depending on the situation on site, it may be necessary to adjust the sensitivity of the orientation sensor.
•
Press and hold the "
S
" key for 6 seconds.
-
> “
-
-
-
”
appears on the display
•
Release the "
S
" key. And quickly follow up by pressing key "
3
"
-
> “
G
—
2
”
appears on the display (default sensitivity).
•
Press the "
UP
" or "
DOWN
" button to change or deactivate the sensitivity.
-
> The sensitivity has 5 levels
:
“
G
-
0
”, “
G
-
1
”, “
G
-
2
”, “
G
-
3
”, “
G
-
4
”,
“
G
-
0
” =
detection sensor is deactivated.
“
G
-
1
” =
least sensitivity level,
“
G
-
4
” =
most sensitive level.
•
Press the "
S
" key
-
> the setting is saved
Note on sensitivity setting: A reset turns the value back to G
-
2.
Please ensure that the HAT can move freely and unhindered at all time.
Prior to any change involving electrical components, cut the desk from power firts.
In case of malfunction stop using the HAT immediately, cut power and contact customer servive.
Содержание eUP 3
Страница 12: ...Nowy Styl eUP 3 EN DE PL 12 Table top assembly Montage der Tischplatte EN DE 6 9 D H 2 D...
Страница 13: ...Nowy Styl eUP 3 EN DE PL 13 Control box assembly Montage der Steuereinheit EN DE 7 6 G 13 E...
Страница 33: ...Nowy Styl eUP 3 EN DE PL 33 Monta blatu PL 6 9 D H 2 D...
Страница 34: ...Nowy Styl eUP 3 EN DE PL 34 Monta sterownika PL 7 6 G 13 E...
Страница 44: ...Nowy Styl eUP 3 EN DE PL 44...