NVIP
-
2H
-
6732M/LPR Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
11
2.5. Camera installation
-
general guidelines
1.
Place the mounting template on the surface on which the camera is to be installed and mark the
drilling points.
2.
Drill holes for mounting screws and cables in the marked places
3.
Drill a hole for the signal cable at the connection point (if necessary)
4.
Connect the cables and fix the camera foot using the provided pegs and screws
5.
Loosen the lock screws "A"
6.
Adjust the camera position
7.
Tighten the "A" lock screws
8.
Adjust the field of view with buttons "T" and "W" (described in point 2.3.)
Caution!
Pay particular attention to the surface to which is attached the camera to have the appropriate capacity.
Caution!
In the case of installation on uneven / rough surfaces, it is recommended to additionally seal the place
of mounting the camera foot with sealing compound. Pay particular attention to the mounting holes
and if they are through, they should also be sealed.
Caution!
The declared tightness class of the camera applies to its housing and does not take into account the
possibility of moisture penetrating the camera through the connection cables. Securing the cables by
e.g. sealing them with an appropriate mass or hiding them in a sealed container is the responsibility of
the person installing the camera. The manufacturer is not responsible for any damage or damage to the
camera caused by failure to fulfill the above
-
mentioned obligation, which at the same time means that
they are not subject to warranty repairs.