NVIP
-
2H
-
6732M/LPR Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
20
RESTORING FACTORY DEFAULTS
6. RESTORING FACTORY DEFAULTS
6.1. Restoring factory settings using the www panel
Resetting the camera to factory settings returns the camera settings to the factory default values. If you
check the selected "Keep" option, you can keep the network settings, security configuration or image
configuration unchanged. The option to restore factory settings is in the tab "Config
-
> Maintenance
-
>
Backup and Restore
-
> Factory Settings".
6.2. Restoring factory settings using NMSiptool application
Using NMSiptool (version 1.39 or higher), the user can restore factory settings. This is done by
selecting the camera, right
-
clicking and selecting "Restore default configuration". Then, within 30
seconds of selecting the option, disconnect the cameras from the power supply and reconnect.
6.3. Factory reset with button
In order to restore factory defaults for the camera please follow the instructions:
•
Remove the cover covering the connectors and buttons.
•
Press the RESET button and hold on for 10 seconds
•
Release button
•
Attach the cover paying attention to the correct position of the gasket
•
Log on after approx. 30 seconds using default IP address (http://192.168.1.200) and default user
name (root) and password (pass)
Содержание NVIP-2H-6732M/LPR
Страница 1: ...Quick start guide NVIP 2H 6732M LPR ...