48
N-563 S
Installation
Menu A:
Set open time
Only in conjunction with function ‘Automatic close’.
1.
Select menu item “A”.
After approximately 2 seconds, the display fl ashes and shows the set value of the operating mode.
2.
If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu value
Open time (without warning time 10 seconds)
0
0 s
1
10 s
2
30 s
3
60 s
4
90 s
5
120 s
6
150 s
7
180 s
8
210 s
9
240 s
3.
Press the programming button (PROG button) (D).
The value “H” is displayed.
Menu H:
STOP-A settings
1.
Select menu item “H”.
After approximately 2 seconds, the display fl ashes and shows the set value of the operating mode.
The factory setting is “0”.
2.
If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Value
Description
Remarks
0
ENS-S 8200 or Extra 412 (with 8k2 resistor) connected to STOP-A input
(terminal G)
1
Jumper or ENS-S 1000 connected to STOP-A input (terminal G)
3.
Press the programming button (PROG button) (D).
The display shows “0”. End of menu (if necessary, continue with power learning cycle).
Содержание N-563 S
Страница 1: ...N 563 S WN 933001 02 6 50 05 2019...
Страница 142: ...142 N 563 S...
Страница 143: ...143 N 563 S...
Страница 144: ...TORMATIC Eisenh ttenweg 6 44145 Dortmund www tormatic de...