47
Installation
N-563 S
Menu 9:
Adjustment other operating modes
1.
Select menu item “9”.
After approximately 2 seconds, the display fl ashes and shows the set value of the operating mode.
The factory setting is "0”
2.
If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu
value
Description
Remarks
0
Normal operation
Factory settings
1
Normal operation
with ventilation
settings*
Allows the ventilation of the garage. In this mode, the garage door is
approximately 10 cm wide open. To start up the ventilation setting, press
the second button on the hand transmitter or use a DuoControl/Signal 111
(accessories) setting* that must be programmed in Menu 2.
The garage door can be closed at any time using the hand transmitter.
The garage door closes automatically after 60 minutes.
2
Partial opening of
side sectional door*
In this mode, the garage door is approximately 1 m wide open. To start up
the partial opening, press the second button on the hand transmitter or use a
button of DuoControl/Signal 111 (accessories)* that must be programmed in
Menu 2.
5
OPEN-CLOSE
operation
After pulsing in CLOSE position, the drive starts and the door moves into end
position OPEN. Another impulse entry during drive has no effect and the door
continues to open. After impulse entry in OPEN position, the door closes. On
impulse entry during closing, the door stops and starts again.
6
Automatic closing
(‘AR’)**
Impulse always causes an opening of the door. After the hold-open time and
warning time (setup menu A) the door closes automatically.
An interruption of the photoelectric sensor during closing causes stop and
reverse direction. Interruption during opening drive has no effect.
7
Automatic closing
(‘AR’)**
Function as in point 6, however, an interruption of the photoelectric sensor
during open time causes early termination of open time and the warning time
starts.
8
Automatic closing
(‘AR’)**
Function as in point 7, however, an impulse during open time causes early
termination of open time and the warning time starts.
9
Automatic closing
(‘AR’)**
Same function as 8, but without early warning phase.
Remarks
:
- *: The second button of the transmitter must be reset after changes in operating modes 1 or 2.
- **: A photoelectric sensor must be installed.
3.
Press the programming button (PROG button) (D).
In setting 0, 1, 2 and 5 value “H” is displayed. Continue with menu “H”.
In setting 6, 7, 8 and 9 value “A” is displayed. Continue with menu “A”.
Warning:
Automatic door - Do not stop in the movement area of the door, because it may start
unexpectedly!
Содержание N-563 S
Страница 1: ...N 563 S WN 933001 02 6 50 05 2019...
Страница 142: ...142 N 563 S...
Страница 143: ...143 N 563 S...
Страница 144: ...TORMATIC Eisenh ttenweg 6 44145 Dortmund www tormatic de...