4. Input STOP-B
This input activates the automatic reversal of the drive during closing.
H
- Connection 4-wire photoelectric sensor (e.g. LS5)
- +
-
+
8k2
G // H - Connection of photoelectric sensor LS2 (please refer to the
connection points of the photoelectric sensor manual for use of
other photoelectric sensors)
8k2
5. Power supply 24 V DC, max. 100 mA (switched)
I
- Connection for e.g. 24 V signal light (accessory)
8k2
6. Power supply 24 V DC, max. 100 mA (permanent)
I
- Connection for e.g. external receiver (accessory)