18
19
Cover
Screws
Clips
Display
Cable
Meter cable
Turn valve knobs
clockwise using
allen wrench
Brine line
Bypass
Top cone
1.
Unscrew the 2 screws from
the cover .
6.
Remove the clips and
screws that connect valve
and bypass
2.
Disconnect display cable.
7.
Remove the bypass from the
valve
3.
Remove cover.
8.
Remove the control valve.
4.
Bypass the water flow to the
conditioner by turning the
valve knobs clockwise.
5.
Remove the brine line.
11.
Remove the top cone.
Before Servicing
1.
Turn off water supply to conditioner :
a.
If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line, then close the valves at the conditioner inlet & outlet.
b. If the conditioner has an integral bypass valve, put it in the bypass position.
c. If there is only a shut-off valve near the conditioner inlet, close it.
2.
Relieve water pressure in the conditioner by stepping the control into the backwash position momentarily. Return the control to the In Service position.
3.
Unplug Electrical Cord from outlet.
4.
Disconnect drain line connection.
SERVICING VALVE