EconoFlo Water Conditioner Installation
In
Out
Cold (Raw water)
Cold (Filtered water)
Check Valve
Water Heater
Hot (Soft Water)
Water Softener
Water Filter
In
In Out
Out
Cold (Soft Water)
To Outside Faucet
*
Outlet
Inlet
NOTICE - THERE ARE RAISED
ARROWS ON THE BYPASS
ASSEMBLY INDICATING
DIRECTION OF WATER FLOW
*NOTE
Check local plumbing codes
in regards to requirements
for use of Check Valve or
back flow prevention or
vacuum breaker
Connect Conditioner to the HousePlumbing
Any solder joints near the valve must be done before connecting any piping to the valve. Always leave at least 6” (152 mm)
between the valve and joints when soldering pipes that are connected to the valve. Failure to do this could cause damage to the valve.
CAUTION!
Never insert drain line
directly into a drain, sewer line, or trap.
Always allow an air gap between the drain
line and the wastewater to prevent the
possibility of sewage being back-siphoned
into the conditioner.
NOTE
Waste connections or drain
outlet shall be designed and
constructed to provide for
connection to the sanitary
waste system through an
air-gap of 2 pipe diameters
or 1 inch (22 mm) whichever
is larger.
INSTALLATION