16
Setting up XLP 50x
Setup the printer for rewinder-use by performing the following steps:
Reversing the direction of rotation
on page 16.
on page 18.
How to perform the steps is explained in the following.
A complete description of the parameters can be found in chapter
"Parameter menu” in the user manual of the printer.
Activating the rewinder
CAUTION! - Selecting a non-existent option can cause the device to
malfunction!
1.
Set
Options > Selection > Periph. device
to “Rewinder”.
Don´t select “Intern Rewinder” by mistake, which activates the internal
rewinder of the printer.
Afterwards, the parameter
Options > Rewinder > Rewind direction
is automatically
called.
2. Select the desired rotation direction (
Printing inside
or
Printing outside
).
Default setting =
Printing outside.
The rewinder is activated now. Other previously activated options are
automatically deactivated.
Reversing the direction of rotation
1. Call
Options > Rewinder > Rewind direction
.
2. Select the desired rotation direction and acknowledge the selection.
Checking the sensor current setting
Call
SERVICE FUNCTION > Rewinder values
.
Rewinder Values
xxx <--------------------> yyy
•
xxx = Sensor value in zero position
•
yyy = Sensor value in final position (Dancer arm at the printer side limit)
The difference yyy – xxx must
at least
be 80 (best: 100). If the difference is
less, the sensor current setting must be changed, see chapter Setting the