Data Logs
Chapter 6
EuroPak-15a Receiver User Manual Rev 5
79
Recommended Input:
LOG CLOCKMODELA ONTIME 1
Example Output:
#CLOCKMODELA,COM1,0,55.0,FINE,1048,497224.500,
00000128,879E,0;VALID,0,497224.500,497224.500,6.59596736E-01,-
9.29232987E-02,-3.4000,4.6302,1.1900,-
4.5002,1.1900,2.15673338E-01,-7.90256149E-01,-
4.5002,-7.90256149E-01,4.7602,-2.902,-1.03659974E-
01,FALSE*f33b4465
Table 36: Clock Model Status Values
Table 37: Constellation Change Flag Values
ASCII
Binary
Description
VALID
0
The clock model is valid
CONVERGING
1
The clock model is near validity
ITERATING
2
The clock model is iterating towards validity
INVALID
3
The clock model is not valid
ERROR
4
Clock model error
ASCII
Binary
Description
FALSE
0
There has not been a change in the constellation
TRUE
1