Examples:
LOG COM1 PSRPOSA ONTIME 7 2.5 HOLD
LOG COM3 PRSPOSA ONCE
The first example configures the EuroPak-15a to output the
PSRPOS
log in
ASCII
format to COM1 at 7 second
intervals offset by 2.5 seconds (output at 2.5 seconds then 9.5 seconds and so on). The second example outputs
the log only once on COM3.
Table 27: Log Trigger Values
Table 28: Log Hold Values
ASCII
Binary
Description
ONNEW
0
Output when the message is updated (not
necessarily changed).
ONCHANGED
1
Output when the message is changed.
ONTIME
2
Output on a time interval.
ONNEXT
3
Output only the next message.
ONCE
4
Output only the current message.
ASCII
Binary
Description
NOHOLD
0
Allow log to be removed by the
UNLOGALL
command.
HOLD
1
Prevent log from being removed by the
UNLOGALL
command.