46
EuroPak-15a Receiver User Manual Rev 5
Chapter 5
Commands
Syntax:
Message ID: 229
Example:
AGCMODE L1 MANUAL 40 50
Table 17: Antispoofing Flag Values
AGCMODE
FREQUENCY
MODE
[
PULSEWIDTH
LOADVALUE ]
Field
Field
Name
Valid Values
Description
Format
Binary
Bytes
Binary
Offset
ASCII
Binary
1
header
This field contains the
Abbreviated ASCII
command name. See
H
0
2
frequency
See
Specifies which signal
type to apply the
command to.
Enum
4
H
3
mode
See
Specifies whether to
use the default or
custom values for the
pulse width and load
value.
Enum
4
H+4
4
pulsewidth
35 to 262144
Pulse width. A value is
only required when the
mode
field is set to
MANUAL.
Float
4
H+8
5
loadvalue
35 to 262144
Modulus load value. A
value is only required
when the
mode
field is
set to MANUAL.
Float
4
H+12
ASCII
Description
FALSE
Antispoofing is disabled.
TRUE
Antispoofing is enabled.